Clean Visual check As needed
6. Maintenance
6.1 General notes
The timed lubricators and the oil supply unit
are generally maintenance-free, though a
visual check should be performed at regular
intervals.
6.2 Tools required
Pressure gauge with a measuring range
of 0 to 60 bar, measurement connector
G 1/4”
Open-end wrench, WAF 30, for vent plug
on the timed lubricator
Open-end wrench, WAF 30, for ilter body
Hexagon socket screw key, WAF 4, for
replacing the 4/2 directional control valve
Pin, max. ø 3,5 mm, for manually switch-
ing the 4/2 directional solenoid valve
6.3 Maintenance schedule
6. Maintenance
Maintenance area Maintenance
Task
Comments
interval
Timed lubricator
Timed lubricator
Weekly
Electronics
See engine manufacturer's operating
instructions
Pressure sensor
See Chapter 6.4.1
4/2 directional solenoid valve
See Chapter 6.4.2
Oil supply unit
Oil supply unit
Weekly
Compare with engine manufacturer's
instructions
Filter replacement
See Chapter 6.5.1
Gear pump replacement
See Chapter 6.5.4