TimeZone

Digital Timer Control Panel

Installation Instructions and 

Operation Manual

This control panel must be installed and serviced by a licensed electrician in 

accordance with the National Electric Code NFPA-70, state and local electrical codes.

UL Type 4X enclosures are for indoor or outdoor use.  

Warranty void if panel is modified.

English 1

            For information regarding operation,

            available options, or servicing

            questions, please call an 

            SJE Rhombus customer service   

            technician:

1-800-Rhombus (1-800-746-6287)

Monday-Friday, 7:00 AM to 6:00 PM Central Time

SJE Rhombus offers a five-year limited warranty.  

For complete terms and conditions, please visit www.sjerhombus.com. 

Products returned must be cleaned, sanitized, or decontaminated as necessary 

prior to shipment to ensure that employees will not be exposed to health hazards 

in handling said material.  All applicable laws and regulations shall apply.

?

Specifications

Operation: 

Four Timers available

 

       (4 x ON/OFF cycles/day) 

Input Voltage: 

100 to 250Vac. 50/60Hz

Pump Ratings: 

0.5HP ~ 3HP (6~20FLA)

•  1/2HP ~1.5HP at 110Vac, 50/60Hz
•  1/5HP ~ 3HP at 230Vac, 50/60Hz

Power Relay: 

2 pole, 25A rated

Operation Temperature: -

10

 to 50

 

Part Number / Circuit Breaker: 

1067561S / 2 pole 16A for pumps rated for 0-12A
1067560S / 2 pole 25A for pumps rated for 9-20A

Clock: 

Real Time clock with Super Capacitor power 

            backup (5 days)

Accuracy: 

Turn ON/OFF time set accuracy (1 min)

Enclosure: 

Thermoplastic, TYPE 4X/IP65

                    (20.3 x 15.2 x 10.2 cm)

                           

English 4

Operatation Guide

A. When turning the knob clockwise slowly, increment by 1 min

B. When turning the knob clockwise faster than A., increment by 10 min

C. When turning the knob clockwise faster than B., increment by 1H

D. When turning the knob clockwise the fastest possible: increment by 4H

E. Same logic when turning the knob counterlockwise (decrease the value)

F.  If there is no operation for 20 sec, the display will return to the main screen

G. The service function is used for alerting the user when it is time to change a filter

     or to serivce the equipment after the accumulated run time is reached.

Main Screen

Rotate

Rotate

Rotate

Rotate

Escape

Escape

Escape

Escape

Escape

Escape

Escape

Escape

Escape/Rotate

Enter

Enter

Enter

Enter

Enter

Enter

Enter

Enter

Save and return

to Main Screen

Timer 2, Timer 3, Timer 4 same setup method as Timer 1

Rotate to change filter or service number

Rotate to change START TIME

Rotate to change STOP TIME

Rotate to change CLOCK (H+MIN), see notes A to E

See notes G

The icon        will flash on main screen when filter or service timer done,

push and hold ESC button 4 

seconds to reset the filter or service time.

Save and return

to Main Screen

Notes :

Save and return

to Main Screen

Содержание TimeZone

Страница 1: ...z Power Relay 2 pole 25A rated Operation Temperature 10 to 50 Part Number Circuit Breaker 1067561S 2 pole 16A for pumps rated for 0 12A 1067560S 2 pole 25A for pumps rated for 9 20A Clock Real Time clock with Super Capacitor power backup 5 days Accuracy Turn ON OFF time set accuracy 1 min Enclosure Thermoplastic TYPE 4X IP65 20 3 x 15 2 x 10 2 cm English 4 Operatation Guide A When turning the knob...

Страница 2: ... is the same as the rating of the pump motor being installed Ensure that the rated Amps of the motor does not exceed the rating of the control panel 2Connect the following wires to the proper terminal positions Incoming power to the circuit breaker Motor Pump power to Motor See schematic label on inside cover of the control panel for details CAUTION Technical support service questions 1 800 Rhombu...

Страница 3: ...n Precisión de ajuste de tiempo de encendido apagado 1 min Gabinete Termoplástico TIPO NEMA 4X IP65 20 3 x 15 2 x 10 2 cm Español 4 Guía de Operación A Cuando gire la perilla lentamente en sentido horario incremente en 1 minuto B Cuando gire la perilla en sentido horario más rápido que A incremente en 10 minutos C Cuando gire la perilla en el sentido de las agujas del reloj más rápido que B increm...

Страница 4: ...e entrada sea la misma que la del motor de la bomba que se está instalando Asegúrese de que los amperios nominales del motor no excedan la capacidad nominal del panel de control 2Conecte los siguientes cables a las posiciones de terminales adecuadas Energía entrante al disyuntor Poder de Motor Bomba al motor Consulte los dibujos eléctricos en la cubierta interior del panel de control para obtener ...

Отзывы: