Tank Alert

®

 XT Indoor/Outdoor Alarm

Terminal Block Option

 

Wiring Instructions

INSTALL THE FLOAT SWITCH AND ALARM

Follow Tank Alert

®

 XT Indoor/Outdoor Alarm Installa-

tion Instructions included.

INSTALL THE PUMP SWITCH

NOTE:

 Electrical rating of pump must not exceed 20

amps at 120 VAC or 20 amps at 230 VAC.

1.

Follow mounting instructions included with pump
switch.

2.

Determine the type of pump switch to be installed.
Select the installation diagram from Figure A that
corresponds to the type of pump switch being
installed.  Run wires from pump switch through
conduit as shown in Figure A:

Two-Wire Pump Switch Wiring:

 Using positions on

the right side of the terminal block, connect the black
wire to position 6, the white wire to position 7 as
shown in Figure A (left diagram).

Double Float

®

 Wiring:

 Using positions on the right

side of the terminal block, connect the black wire to
position 6, the white wire to position 5, the red wire to
position 7 as shown in Figure A (right diagram).

INSTALL THE PUMP

1.

Run wires from pump through the same conduit as
the pump switch wiring as shown in Figure B.

2.

On the left side of the terminal block, connect the
black wire to position 7, and on the right side of the
terminal, connect the white wire to position 5, and
the green wire to position 8 as shown in Figure B.

3.

Run wires from pump power source through
conduit as shown in Figure C. This source should be
on a separate circuit from alarm power.

4.

Using positions on the left side of the terminal
block, connect the white wire to terminal position 5,
the black wire to terminal position 6, and the green
wire to terminal position 8 as shown in Figure C.

5.

Turn power on and tip pump switch to check
installation. Turn power off.

6.

Finish installing alarm panel according to Tank
Alert

®

 XT Installation Instructions.

NOTE:

 Route pump power and alarm power cords

through conduit on left. Route control switch, pump
switch, and pump cords through conduit on right.

ELECTRICAL  SHOCK  HAZARD

Disconnect power before installing or servicing
this product. A qualified service person must
install and service this product according to
national and local electrial codes. Do not
install in hazardous locations as defined by
the National Electrical Code, ANSI/NFPA 70.

2-WIRE

PUMP SWITCH

FIGURE A

DOUBLE FLOAT®

PUMP SWITCH

OR

FIGURE B

WIRE SIZE 12-24 AWG

WIRE SIZE 12-24 AWG

WIRE SIZE 12-24 AWG