background image

 

 

 

P a g e

14 | 

© 2013 SiTime Corporation. All rights reserved. 

Time Machine User’s Manual 

 

Data Log Mode 

Data  log  mode  allows  storing  additional  information  about  programmed  parts  and  order 

during  batch  programming.  To  switch  to  the  data  log  mode  please  select 

View > Data  Log

  as 

shown in the figure below.  

 

Data  Log  Utility 

has  fields  for  entering  ordering  information,  operator  lot  information  and 

part  number.  Fields  marked  with  red  asterisk  should  be  filled  mandatory.  Once  required 

information is entered, it’s possible to start programming session.  

 

At the beginning of programming session 

Part Number Generator 

appears showing decoded 

Device status 

Sessionstart button 

Operator’sname 

Quantityof parts to be 

programmed 

Lot ID 

Operation selection 

Channel selection 

Sample request number 

Part number field 

Customer FP part number 

Message window 

Operation indicator 

Mean part programming 

time 

Session start time

 

Session end time 

Session yield 

Quantity of processed parts 

(prog failed)

 

Содержание SIT6100DK

Страница 1: ...ess mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer IC Socket Relay Connector Our parts cover such applications as commercial industrial and automotives areas We are looking forward to setting up business relationship with you and hope to provide you...

Страница 2: ...Revision 2 11 11 06 2015 2015 SiTime Corporation All rights reserved Time Machine II User s Manual TimeMachineII User sManual ...

Страница 3: ...re Connection 6 Driver Installation 7 Working With the Time MachineSoftware 8 User Interface features 8 Entering Part Number 10 Part Number Generator 11 Part Programming 12 Tracking ID 12 Auto Detect Mode 12 Viewing Operation Logs 13 Data LogMode 14 Viewing DataLogs 15 Software Updates 17 Troubleshooting 18 The Time Machine fails to start 18 Programming generates a FAIL message 18 Reporting a bug ...

Страница 4: ...nformation on how to select and order FP parts Please contact your SiTime sales representative for large volume production orders The Time Machine II has not been tested for EMC compliance EMI radiation susceptibility or any temperature and humidity cycling The recommended temperature range is 20 C to35 C Package Contents Your Time Machine II package consists of the following items 1 SiTime Progra...

Страница 5: ... x 5 0mm 6 pin Figure 3 Time Machine socket card SiT6161DK Supports 2 0mm x 1 6mm 4 pin and 2 5mm x 2 0mm 4 pin packages Figure 4 Time Machine socket card SiT6162DK Supports G package 2 7mm x 2 4mm 4 pin and 3 2mm x 2 5mm 4 pin packages Figure 5 Time Machine socket card SiT6163DK Supports G package 2 7mm x 2 4mm 4 pin and 3 2mm x 2 5mm 6 pin packages Pin1 location Part outline Arrow indicates Pin1...

Страница 6: ...page http www sitime com tm sw and download SiTime installer Run downloaded installer and you will be brought to screen below Press Install button right after Time Machine Software Note The Time Machine requires NET Frameworkinstalled on your computer Install NET Framework before installing Time Machine Software Green checkmark will appear if NET Framework will be present on target PC or after ins...

Страница 7: ...Time Machine software from the TMII product page on SiTime website In this case you should install it by double clicking the setup file and following the on screen installation instructions Hardware Connection Connect the SiTime Programmer to your PC using the USB cable The power light will be illuminated The first time the SiTime Programmer is connected the Windows Found New Hardware notification...

Страница 8: ...tallation The first time the software is started the driver installation will be required Time Machine software will install all required drivers automatically The Windows Security notification window will appear Please check Always trust software from sitime corp and press the Install button ...

Страница 9: ...e log viewer TimeMachine Auto Detect enables disables parts auto detection mode TimeMachine Settings launches available part families configuration TimeMachine Exit quits the software Help View Manual opens this User s Manual Help Supported devises shows the list of devices supported by Time Machine Additional options Device status Operation indicator General software help Tracking ID field Part N...

Страница 10: ...tes checks for software updates requires internet connection Help About SW FW versions only SW version is shown if the SiTime Programmer is not connected Device status shows status of the SiTime Programmer Connected Disconnected Operation indicator indicates operation status and results READY BUSY PASS FAIL Message Window reflects operation result and part detection result The main UI can run with...

Страница 11: ...hen the part number is invalid You cannot program the device with an invalid part number Time Machine II software will alert you with this icon if the part you are trying to program contains non default drive strength With the correct part number in the Part Number Field Time Machine II software will automatically detect which FP Field programmable or blank family you are going to use to program t...

Страница 12: ... FP part in the specific Channel socket you are entering the part number in The PN generator window will appear Select the desired part family from the drop down list at the top of the Part Number Generator window Specify desired frequency and other configuration parameters and click OK The generated part number will be automatically pasted into the Part Number field of the appropriate Channel The...

Страница 13: ...ally following any Programming operation During Programming and Verification procedures the active channel window will dim and all controls in the channel dialog boxes will be disabled The Operation indicator will read BUSY as shown below Tracking ID The main UI includes an optional Tracking ID field to help you track programming history After entering the part number but before programming you ma...

Страница 14: ...ed for part frequency estimation If an already programmed part is inserted in the socket the message will display the estimated part frequency Viewing Operation Logs Time Machine stores records of all parts programmed and you can access them at any time in order to view programming history In order to launch the Log Viewer please select TimeMachine View Logs on the main UI Note Auto Detect estimat...

Страница 15: ...part number Fields marked with red asterisk should be filled mandatory Once required information is entered it s possible to start programming session At the beginning of programming session Part Number Generator appears showing decoded Device status Sessionstart button Operator sname Quantityof parts to be programmed Lot ID Operation selection Channel selection Sample request number Part number f...

Страница 16: ... programming is done operator should place new FP part and press Program Next button Programming session ends when number of programmed parts reaches Actual Quantity entered or Stop button is pressed At programming session end programming information is stored to the log Viewing Data Logs Data logs can be displayed by opening Log Viewer TimeMachine View Logs and selecting Data Log tab ...

Страница 17: ...ing the software launch or when you connect the device It is strongly recommended that you perform an update immediately Do not close the application until the update process is complete The FW update process will start after clicking OK Note Windows Found New Hardware notification may appear during the firmware update In this case please wait until driver installation is complete ...

Страница 18: ... This feature requires an internet connection You can check for updates manually at any time by clicking Help Check for Updates under the menu in Time Machine software If a software update is available press Yes to download the update The installation will start automatically after finishing download process You will also be notified if your Time Machine software is up to date ...

Страница 19: ... generates a FAIL message Make sure you are using an appropriate Field Programmable FP part in the correct socket and that part has not been programmed already If these conditions are met and programming fails try replacing the device Reporting a bug Time Machine has an automatic crash report sending feature If the system crashes please send a report to SiTime Please provide additional information...

Страница 20: ...nical requirements of these directives 5 THE PLATFORM AND ITS ACCOMPANYING SOFTWARE AND DOCUMENTATION ARE PROVIDED ON AN AS IS BASIS WITH ALL FAULTS AND WITH NO WARRANTY WHATSOEVER SITIME AND ITS LICENSORS EXPRESSLY DISCLAIMS ALL WARRANTIES WHETHER EXPRESS IMPLIED OR STATUTORY INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE TITLE AND NON INFRINGEMENT...

Отзывы: