background image

1

 

                                                                                                                                 

GS869

 

MANUAL

 

REV

 

E

 

Gas Leakage Alarm User’s Manual 

Model : GS869/GS869A 

 
 
 
 

BS EN50194-1:2009 

Licence No.: KM642335 

 
 
 

Diagram 1

                                             

Thank you for purchasing this gas detector, which is intended to detect 

leakage of natural gas.

 

The detector that must connected to the mains power is 

intended for installation in domestic premises (including static caravan holiday 
homes).  

Please take a few minutes to read the user’s manual thoroughly and 

familiarize yourself and your family with its operation. And save it for 
future reference. 

Product Specifications: 

Power Source     

 

: AC 220-240V / 50-60Hz 

Sensor 

type 

   : 

Semiconductor 

Detector Gas 

 

 

: Natural Gas (Methane) 

Sensitivity    

 

 

: 6% LEL (Lower Explosive Limit) 

Sound Level 

 

 

: >85dB at 1 meter 

Power Consumption  

: <4W 

Dimension 

   : 

117.4×77.4×36.3mm 

Temperature   : 

-10

~40

 

Humidity 

   : 

0~95% 

RH 

Protection 

level 

  : 

IPX2D 

Product 

Life   : 

Years 

Accessory (optional)  

: Solenoid valve 

 
Solenoid valve Specifications (If applicable): 

Control type: 

 

Normally open 

Actuation voltage:    DC 9V pulse voltage 
Temperature:    

-10

~ 60

 

Reset style:   

 

manual reset 

Maximum pressure:  50Kpa 
Flux: 

   25m

3

/h 

Connection style: 

screw thread 

 

Status 

All statuses of the detector are showed in the summary table. 

Summary Table 

Status Illustration 

Green 

LED 

Yellow 

LED 

Red  

LED 

Horn 

Solenoid 

valve 

Self-Test Power 

on  ON 

ON ON Chirp 

once open 

Preheat 

About 180 seconds

Light 

0.5s/1s

OFF OFF

 

OFF open 

Standby Normal 

condition 

Constant 

on 

OFF OFF 

OFF 

open 

Test 

Press key when 

Preheat or Standby

Constant 

on 

OFF 

Light 

0.5s/1s

Synchronized 

with Red LED 

close 

ALARM 

Gas detected 

Constant 

on 

OFF 

Light 

0.5s/1s

Synchronized 

with Red LED 

close 

Silence 

Press key when 

ALARM 

Constant 

on 

OFF 

Light 

0.5s/1s

OFF close 

Sensor 

Fault 

The detector must 

be replaced 

Constant 

on 

Constant 

on 

OFF 

chirp once per 

30 seconds 

open 

End of life

The detector must 

be replaced 

Constant 

on 

Constant 

on 

OFF 

chirp third times 

per 30 seconds 

open 

Power off 

The power wire is 

unplugged 

OFF OFF OFF 

OFF 

open 

Содержание GS869

Страница 1: ...d valve Solenoid valve Specifications If applicable Control type Normally open Actuation voltage DC 9V pulse voltage Temperature 10 60 Reset style manual reset Maximum pressure 50Kpa Flux 25m3 h Connection style screw thread Status All statuses of the detector are showed in the summary table Summary Table Status Illustration Green LED Yellow LED Red LED Horn Solenoid valve Self Test Power on ON ON...

Страница 2: ...ly may be reinstated and the solenoid valve must be manual reset Even if the apparatus is fitted with a triggering device for example for closing a solenoid valve on the incoming gas pipe the same procedure as described above should be followed The detector should not be installed directly above cooking appliances in any outside location in an enclosed space e g in a cupboard or behind a curtain d...

Страница 3: ...hlorine gas Hydrogen chloride alkaline metals water alcohol based products propane isobutene isopropanol ethylene benzene toluene ethyl acetate paints thinner solvents adhesives hair sprays after shaves perfumes and some cleaning agents etc Warning If water freezes on the sensing surface the sensing material would crack altering characteristics Warning The detector cannot properly operate in a zer...

Страница 4: ...r will be in self detection for about 3 minutes During this period green LED is flashing When it stops the green LED is constant on and the detector is ready for use Additionally any changes to the gas installation e g fitting of an automatic gas shut off valve must be carried out by a person qualified to the national regulations for gas installations Note for installation of solenoid valve To pre...

Отзывы: