31
8.7.
Parameters
Submenu where the user can read and set the water parameter.
With the button
you can switch from screen 1 to screen 2.
Screen 1:
➢
Flow rate:
displays the flow rate in mc/h.
➢
Transmittance:
shows the water transmittance read by the UVT meter sensor in %.
➢
Flow meter setting :
the UV707MBS2 special board has a 4/20 mA input signal which
describes the water flow rate. The signal can be set:
Touch on
to open 4/20mA calibration popup menu:
Associate the values 4 and 20 mA to the minimum and maximum flow rate input. Touching
"OK", the user calibrates the 4/20 mA input.
➢
Transmittance setting :
the UV707MBS2 special board has a 4/20 mA input signal which
describes the UVT transmittance. The signal can be set:
Touch on
to open 4/20mA calibration popup menu:
Associate the values 4 and 20 mA to the minimum and maximum flow rate input. Touching
"OK", the user calibrates the 4/20 mA input.