![Sistemes Electrònics Progrés s.a. AGRONIC 4000 Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/sistemes-electronics-progres-s-a/agronic-4000/agronic-4000_instruction-manual_1285417038.webp)
38
Among the 40 possible, the number of sensor is
shown in the first line, and at its right the instant value
with the sensor units. Where the sensor is connected
to is shown in the second line.
Sensor 01
0642 Wm
2
Sensor: 04 in the base
Use the up and down arrow keys to move among
the sensors; press “Function” or “View” to exit.
8.5. COMMUNICATION READINGS
[ check the Communication Options pamphlet ]
8.6. SOFTWARE VERSIONS
In this section the series number of the Agrónic
4000 is displayed as well as the software versions of
the programs it features.
NS: 02348 V: 3.00
C107-1 1.00
C97-1 1.00
C102-1 1.00
NS: serial number.
V: version of the Agrónic 4000 program.
C107: version of the analog inputs and outputs.
C97: version of the serial ports.
C102: version of the GPRS modem program.
9. ERASURE
The ERASURE function will be used to cancel the
programming or the totals values. To do so, press the
“Function” key, choose the function by its number (3)
and then press “Enter”.
Programs : 1
Readings : 2
Erasure : 3
Parameters: 4
Manual : 5
Clock : 6
The “Erasure” menu is the following:
ERASURE
Program : 1 All : 2
Totals : 3
To exit any “Erasure” screen press the “Function”
or “View” keys.
Care has to be taken when using this function,
yet important values for the irrigation system working
can be cancelled.
At sector “1” the program number to be erased
will be asked, at sector “2” to erase the whole pro-
grams and at number “3” to erase all the totals. Con-
firmation of the erasure will always be requested.
Are you sure to erase : NO
10. MANUAL
By using the manual function, the following can
be done:
Start the beginning of a program.
Stop a program that is irrigating.
Leave a program out of service; the values of
the irrigation which is taking place will be erased.
Remove a program from the out of service
position.
Stop the system, that it can also be done
with the “STOP” key. The programs are post-
poned and the outputs deactivated.
Remove the stopping system, that can also
be done with the “STOP” key. The programs will
reinitiate at the same place where they stopped.
Set the Agrónic at out of general service,
leaving everything stopped and erasure the values
of the irrigations that are taking place out of the
programs.
Exit the out of general service.
Start the filter cleaning.
Finish the filter cleaning.
Finish the stop by general malfunction.
Finish the stop by flow malfunction.
Finish the stop by meter malfunction.
Finish the stop by fertilizer without control.
Finish the definitive stop of the sectors.
Reinitiate the injection by error in the fertiliz-
ers proportions.
Finish the stop of the filters by filter out of
control malfunction.
Finish the activation of the general alarm
outputs, fertilizer or acid.
Finish the stop of the alarm by EC.
Finish the stop of the injection by pH alarm.
To do so, press the “Function” key, choose the
option by its number (5) and then press “Enter”.
Programs : 1
Readings : 2
Erasure : 3
Parameters: 4
Manual : 5
Clock : 6
The “Manual” menu is the following:
MANUAL Out of service : 1
STOP : 2
Program : 3 End malfu. : 4
Filters : 5
MANUAL Outputs : 6 Advices : 7
To exit any manual screen press the “Function”
or “View” keys.
It is possible to move to another screen from the
“
Out of service”
sector in order to do a general or a
program one.
General : 1 Program : 2
General out of service (Y/N) : NO