5. TECHNICAL CHARACTERISTICS
Power supply
Units for alternating current
Units for direct current
Tension
230 Vac or 115 Vac +5 % -10 % CAT II
12 Vdc +10 % -5 %
Frequency 50-60
Hz
= = =
Energy consumption
Below to 43 VA
Below to 18 W (at rest 1.7 W)
Input
0.800 A, T type, 250 V (slow)
1.5 A, T type, 250 V (slow)
Fuses
Output
6.3 A, F type, 250 V (fast)
6.3 A, F type, 250 V (fast)
Keeping the memory which
can be erased when there is
a power cut
Lithium Battery, at 3 V.
Number
16, extensibles to 24, 32, 48, 64, 80, 96.
Digital
Type
By relay contact, with potential of 24 Vac (External transformer)
Limits
30 Vac / 30 Vdc, 1 Amp, 50-60 Hz, CAT ll
Number 5
or
10
Analog
(option)
Type
By current of 0/4 to 20 mA
Outputs
All outputs have double isolation in reference to the net input.
Number 12
Digital
Type
Optolinked, work at 24 Vac
Number 6
or
12
Inputs
Analog
(option)
Type
4-20 mA (with galvanic separation)
Temperature
0 °C to 45 °C
Humidity
< 85 %
Box model
Built-in model
Heigh 2000
m
Atmosphere
Pollution Grade
2
Weight
(Kg.)
From 3.2 to 6.3
From 4.0 to 5.0
Memory backup
Clock and data
Above to 5 years
DECLARATION OF CONFORMITY
It follows the 89/336/CEE guidelines for the Electromagnetic Compatibility and the
73/23/CEE guidelines of Low tension for the fulfillment of the product security. The fulfillment
of the following specifications was demonstrated as indicated in the Official Diary of the Euro-
pean Communities:
Emissions EN 50081-1:94 EN 55022:1994 Type B Radiated and conducted emissions.
Immunity EN 50082-1:97
EN 61000-4-2 (95)
Immunity to electrostatic discharges.
EN 61000-4-3 (96)
Immunity to the electromagnetic field of radioelectric fre-
quency.
EN 61000-4-4 (95)
Immunity to fast transitional in gusts.
EN 61000-4-5 (95)
Immunity to crash waves.
EN 61000-4-6 (96)
Current injection
EN 61000-4-11 (94)
Variations to the power supply.
Harmonics
EN 61000-3-2 (95)
Current harmonics.
Fluctuations
EN 61000-3-3 (95)
Tension fluctuations (Flickers).
Low tension guidelines:
EN 61010-1
Security requirements of measurement electric units, con-
trol and use in laboratory.
Symbols which may
appear in the product
Protection
earth terminal
Danger, risk of
electroshock
Box ter-
minal
Double
isolation
This symbol indicates that the electrical and electronic equipment should not be disposed of as gen-
eral household waste at its end-of-life. Instead, the product should be handed over to the applicable
collection point for the recycling of electrical and electronic equipment for proper treatment, recovery
and recycling in accordance with your national legislation.