 EDT2411A

Thank you for choosing  

ENDA EDT2411A

 temperature controller. 

  ENDA

 

EDT2411A DIGITAL THERMOSTAT

35x77mm.
On-Off control.
Relay output for cooling or heating control.
Single NTC probe input.
Offset value can be entered for NTC input.
Compressor protection parameters can be entered.
In case of probe failure, output status can be set to 
ON, OFF or periodic.
Upper and Lower setpoint value limits can be 

adjust

ed.

Selectable “Smart Defrost” feature.
Defrosting duration and intervals can be adjusted.
6 Different warning tone selections.
Lower and upper alarm limit can be adjusted to depending
on set value. 
Temperature unit can be selected 

°

C or 

°

F.

Digital input ;
     

-

 E

xternal alarm 

     

-

 I

nitiate defrost 

Transfer device parameter settings with 

ENDAKEY

   

 - 

N

o power-up required. 

RS485 ModBus protocol communication feature (optional).
CE marked according to European Norms.

Please read this document carefully before using this product. The guarantee will be invalidated if the 
device is damaged by not following instructions detailed in the manual. The company shall not be 
responsible for any damage or losses however caused, which may be experienced as a result of the 
installation or use of this product.

CONNECTION DIAGRAM

ENDA  EDT2411A

  is  intended  for  installation  in  control  panels.  Make  sure  that  the  device  is  used

only  for  intended  purpose.  The  electrical  connections  must  be  carried  out  by  a  qualified  staff
and must be according to the relevant locally applicable regulations. During an installation, all of the cables 
that are connected to the device must be free of electrical power. The device must be protected against 
inadmissible  humidity,  vibrations,  severe  soiling  and  make  sure  that  the  operation  temperature  is  not 
exceeded. The cables should not be close to the power cables or components. 

SUPPLY:

NOTE:

184-253V AC 
50/60Hz 4VA

Line

Neutral

230V AC
Supply

 

Switch

Note: 

Cable size: 1,5mm²

Fuse 

F 100 mA 

250V AC

Fuse should 
be connected

1)

 Mains supply cords shall meet the requirements of  

    IEC 60227 or IEC 60245. 

2)

 In accordance with the safety regulations, the power 

    supply switch shall bring the identification of the 
    relevant instrument and it should be easily 
    accessible by the operator.

1

2

Order Code : EDT2411A -          -   -                      

1

2

3

1 - Supply Voltage

     230........230V AC
     110........110V AC
      24.........24V  AC/DC   
      12.........12V  AC/DC

     

SM........10-30VDC / 8-24V AC

      24V.......12V / 24V DC
     

       2-Output 

   

                                         

             

R.........08A  Relay output                 

             P......... 20A Relay output
                                                                  
                     
                                   
                  

3 - Modbus
     

RS........ RS-485 Modbus Available 

                   (Optional / Specify at order) 
     Blank.... N/A

Holding screw 
0.4-0.5Nm 

Equipment is protected throughout
by DOUBLE INSULATION.

ENVIRONMENTAL CONDITIONS

 Height

 Max. 2000m

 Ambient / Storage Temperature

 Relative Humidity

0 ... +50°C/-40 ... 85°C (without icing)

Protection Class

According to EN60529;    Front panel : IP65,  Rear panel : IP20
                                              

 Do not use the device in locations subject to corrosive and flammable gasses.

 Supply Voltage
 Power Consumption

Max. 5VA
2.5mm² screw-terminal connections

   ±1% 
   4 digits, 12.5mm, 7 segment  LED (V2 Code : Blue Display)

 Connection
 Scale
 Sensitivity
 Accuracy
 Time Accuracy
 Display
 EMC
 Safety Requirements 

 EN 61326-1: 2013
 EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)

ELECTRICAL CHARACTERISTICS

-60.0 ... +150.0°C (-76.0 ... +302.0°F)

0.1°C (Can be selected as 0.1

ºC 

or

 1ºC

.) 

±1°C  

CONTROL

 Control Type

 Single set-point control
 On-Off control

 Control Algorithm
 Hysteresis

 Adjustable between 1 ... 20.0°C. 

  Life Expectancy for Relay

OUTPUTS

HOUSING

 Housing Type

 Suitable for flush -panel mounting

 Dimensions  

 W77xH35xD61mm 

 Weight 

 Approx. 190g (After packing)  

 Enclosure Material

 Self extinguishing plastics.

 While cleaning the device,solvents (thinner,benzine,acid etc.) or corrosive materials must not be used

.

Relay Output

For EDT2411A-X-R ; Without load  30.000.000 mechanical; 
                               250V AC, 8A resistive load 100.000 electrical operation.

For EDT2411A-X-P ; Without load  10.000.000 switching;
                               277V AC,20A (for resistive load) 100.000 electrical operation.

                                                  
                                          

For EDT2411A-X-R ; Relay : NO+NC 250V AC,8A  (resistive load),
                                       1/2HP, 

0.37KW

 240V AC   (inductive load)

 
                                                     
                                          

For EDT2411A-X-P ; Relay : NO 277V AC,20A        (resistive load),
                                       1/2HP, 

0.37KW

 250V AC   (inductive load)

                                              
                                          

Max. humidity 80% for temperatures up to 31°C decreasing linearly to 
50% relative humidity at 40°C.

DIMENSIONS

 Note:  

1)

 Panel thickness should

be maximum 7mm.

2)

 If there is no 60mm free

space at the back side of
the device,it would be 
difficult to remove it from
the panel. 

Flush mounting

clamp

For removing mounting clamps:  

Push the flush-mounting 

clamp in direction 

1

 as shown 

in the figure below.Then,pull
out the clamp in direction 

2

 .

 

71,5mm

28,5mm

Panel cut-out

  61mm                    5mm

  Flush mounting
         clamp

Panel

Rubber
 packing

2

Depth

77mm

35mm

1

1

2

3

4

5

6

7

8

9

10

ENDA

 

INDUSTRIAL ELECTRONICS

SN: XXXXXXXXX

EDT2411-230-R

DIGITAL THERMOST

AT

ENDAKEY

230V AC +10% -20%

50/60Hz  5VA

     NTC

 

     GND

11

12

DIG INP

COMPRESSOR

250V AC 8A

RESISTIVE LOAD 

8

68

04

07

70

22

20

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. Barbaros Cad. No:18 Y.Dudullu  34775
ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr