ENDA ATSD02
Rail Mounted Star-Delta Analog Timer.
*
Separate contacts for star and delta connections (OUT1 - OUT2).
*
Star connection to remain active time can be adjusted.
*
Star-delta switching time can be adjusted.
*
6 Different timing unit for star connection (S, 10S, M, 10M, H, 10H).
*
Rail Mounted.
*
Screw-terminal connection.
*
CE marked according to European Norms.
1 / 2
ATSD02-
EN-02-220103
0 ... +50°C/-25 ... +70°C (With no condensation and icing).
OUTPUT CONTROL
ATSD02 - xV
ORDER CODE
E
ND
A
A
TS
D0
2
Y T
IME
OFF T
IME
Y R
ANGE
10
0
20
0
40
0
0
50
0
20
10M
10H
H
10S
M
S
.4
.6
.8
0
1
.2
Power Led
Power
OUT2 NO
OUT1 Led
OUT2 Led
t Y
Power
OUT1 NO
t off
t Y=Y RANGE x Y TIME
t off=OFF TIME
SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Şerifali Mah.
Y.Dudullu 34775
ÜMRANİYE/İSTANBUL-
TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
Barbaros Cad. No:
18
Thank you for choosing
ENDA AT
SD
0
2
R
ail mount
ed
star-delta
analog timer.
Product Basic Code
Rail Mounted Star-delta
Analog Timer
Technical Specifications
Read this document carefully before using this device. The guarantee will be expired by device demages if you don't
attend to the directions
in
user manual. Also we don't accept any compensations for personal injury, material
damage or capital disadvantages.
Max. humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.
ENVIRONMENTAL CONDITIONS
Max. 2000m
IP20, According to EN 60529
Do not use the device in locations subject to corrosive and flammable gasses.
Height
Ambient/storage temperature
Max. relative humidity
Rated pollution degree
ELECTRICAL CHARACTERISTICS
Scale
EMC
İnsulation test voltage
Supply voltage
Power consumption
Connection
Reset time
Accuracy
Safety requirements
90-250V AC 50/60Hz ; 24V AC/DC 50/60Hz
Max. 10VA
Screw-terminal connection.
Depending on the effect of voltage: max %0.2
EN 61326-1:
2012
EN 61010-1: 2010 (pollution degree 2, overvoltage category II)
3kV AC min. 1 minute, 4,2kV DC min. 1 minute.
For Star connection 0-1. For OFF delay time
0, 20, 100, 200, 400, 500 milliseconds.
Max. 0.04 seconds.
Depending on the set value settings:max %4.5
Depending on the effect of temperature :max %1
OUTPUTS
Control outputs (OUT1/OUT2)
Control output state
Life expectancy for relays
Relay: 250V AC,
10
A (for resistive load), NO+NC
Without load
1
0.000.000 operation; 250V AC, 10A resistive load
5
0.000 operation.
OUT1 LED lights up when OUT1 relay is turned on, OUT2 LED lights up when OUT2 relay is turned on.
OUT1 and OUT2 LEDs blinks during OFF time.
CONTROL
Timing function
Timing unit
Y TIME : ON time duration for OUT1 Relay. OFF TIME: OFF time duration for OUT1 and OUT2 relays.
Can be adjusted on device.
For Y TIME Second, 10 seconds, minute, 10 minutes, hours, 10 hours can be selected on device.
HOUSING
Mounting
Dimensions
Weight
Enclosure material
Rail mounted (EN 60715, Th35)
W18xH90xD66mm
Approx. 90g (after packaging)
Self extinguishing plastics.
While cleaning the device,solvents (thinner,benzine,acid etc.) or corrosive materials must not be used.
90-250V AC
24V AC/DC
UV
LV
ATSD02 - xV
Supply Voltage