G 1

 

 

 

 

DL918

控制系統

 

 

 

Outline 

 

 

 

Содержание DL918

Страница 1: ...G 1 DL918 Outline...

Страница 2: ...66 10 Dust Level IP40 Types of Drive Motor 1 Three Phase Sinusoidal Drive AC Servo Motor 500W BLDC 2 3 Needle Position Error of 3 degrees 3 Velocity Command Value 200 5000rpm 4 Tangential Velocity Val...

Страница 3: ...ay LED 3 Sewing Machine 14 Pin Connecter Pin1 OA Pin 8 24V LU25 E 6mm 7 5ohm 5 5Kg mm Trimmer Solenoid LU25 E distance 6mm mpedance 5ohm suction5 5Kg mm Pin2 OB Pin 9 24V GLU36 7mm 8 5ohm 2 5Kg mm Thr...

Страница 4: ...G 4 Electric Controller Block Diagram...

Страница 5: ...rement Decrement Key 3 Forward Stitch Correction 11 Constant Stitching Setting 4 Presser Foot Function When Motor Stop 12 Free Stitching Setting 5 Auto Thread Trimming Function 13 One Shot Automation...

Страница 6: ...15 Enter Constant Stitching Function Set the stitch number Free Stitching 1 Forward tread the front part of foot pedal The machine will run 2 Reset the foot pedal back to original position The machin...

Страница 7: ...imming Presser foot action after thread trimming Forward Stitching Correction Forward stitching as adding stitch before machine stop Special Function Selection Enter Special Function Mode to select fu...

Страница 8: ...LED light LED LED OFF LED Turn off LED light Increment Key A B C D 0 15 0 F Note A 10 B 11 C 12 D 13 E 14 F 15 Stitching number increment from 0 to 15 0 F Note A 10 B 11 C 12 D 13 E 14 F 15 Increment...

Страница 9: ...trimming completed and start next stitching cycle 3 Counter Ratio Selection 1 100 1 043 003 x 043 Set the counter ratio It will be a multiple for the value set in 043 The real value will be 003 x 043...

Страница 10: ...ing cycle at constant stitching the end tacking or thread trimming will not be executed unless depressing backward on foot pedal 12 Mode Selection for Start Tacking A M SU SD A A A One shot sewing M M...

Страница 11: ...the re start must be controlled by foot pedal forward treading 14 Start Tacking Function Selection ON OFF ON 15 A Stitch A Setting for Start Tacking 0 15 3 16 B Stitch B Setting for Start Tacking 0 15...

Страница 12: ...Function Selection ON OFF ON 22 C Stitch C Setting for End Tacking 0 15 3 23 D Stitch D Setting for End Tacking 0 15 3 24 Turns Setting for End Tacking 0 4 2 25 C Stitch C Balance for End Tacking 00 0...

Страница 13: ...stitch in C Section OFF OFF The function is invalid 31 Mode Selection for Bar Tacking A M SU SD A A A One Shot Sewing M M Motor can adjust speed and stop during operation via foot pedal control SU 027...

Страница 14: ...and stop during operation via foot pedal control 38 15 Constant Stitching Function Selection ON OFF OFF 39 Stitches Setting for Constant Stitching 0 250 15 P1 PF P1 P4 15 0 When using P1 PF functions...

Страница 15: ...0 4500 Speed Display Parameter LED Display Function Description Range Unit Default Description Note 47 MAC Sewing Machine Code Selection without with Presser Foot Lifter 11 13 13 Sewing Machine Code S...

Страница 16: ...esser Foot Lifter Type Selection M A M M M Solenoid Type A A 064 FO 065 FC A Pneumatic Type When set at A type 064 FO 065 FC is invalid 64 FO Full On Time Setting for Presser Foot Lifter Solenoid 0 99...

Страница 17: ...edal Delay Time 0 990 ms 100 100ms Set half heeling delay time The default is 100ms 70 HHC Half Heeling Pedal Function Canceling ON OFF OFF ON ON No presser foot lifter at half heeling The trimmer wil...

Страница 18: ...ETY SW NO Safety switch normal open 81 TS Trimmer Solenoid Enabled Angle 0 360 Deg ree 45 82 T1 Delay Time Prior to Trimmer Enabled 0 990 ms 70 85 D1 Thread Tension Solenoid Enabled Angle 0 360 Deg re...

Страница 19: ...Solenoid Advanced Open Angle Start Tacking 0 1440 Deg ree TBD Default will be different by different sewing machine model 102 S2 Solenoid Advanced Close Angle Start Tacking 0 1440 Deg ree TBD Default...

Страница 20: ...Down Position Stop Angle 0 360 Deg ree 25 114 UEG Needle Up Position Stop Angle 0 360 220 117 ER Error Code Record 10 1 10 Record of Latest 10 sets Error Codes 120 FHM Full Heeling Pedal Mode Selecti...

Страница 21: ...D A A A Needle position change with low speed movement B B Needle position change C C Needle upward moving D D Needle upward moving and enable presser foot lifter 126 USA Needle Position Switch Enabl...

Страница 22: ...st OFF time setting 138 UTD Automatic Cycling Test Function ON OFF OFF ON ON Enable automatic cycling test OFF OFF OFF Disable automatic cycling test After power off the cycling test is disable 168 P1...

Страница 23: ...Enable wiper function OFF OFF Disable wiper function F3 Up Down Needle Positioning Selection ON OFF OFF ON ON Needle up positioning OFF OFF Needle down positioning F4 Soft Start Function Selection ON...

Страница 24: ...G 24 Manual...

Страница 25: ...G 25 Constant Stitching Parameter Setting Details...

Страница 26: ...G 26 Special Function Setting Details...

Страница 27: ...G 27 Display Table...

Страница 28: ...onnector Diagram CN102 Motor Power Connector CN701 Motor Encoder Connector 1 U Red 1 A Green 2 V White 2 B White 3 W Black 3 Z Yellow 4 PE Yellow Green 4 5V Red 5 5VGND Black 6 U Brown 7 W Gray 8 V Or...

Страница 29: ...12V 2 Signal 2 GND CH102 Neutral 2 5V 2 GND 3 GND 3 Rx 3 N A 4 N A 4 Tx 4 GND Electromagnetic Valve Trimmer Wiper Reverser Reserved CN705 Foot Lifter CN711 Revere Switch CH701 30V CH703 30V CH705 30V...

Страница 30: ...Measurement and Solution Err 1 Over Current Protection 1 Turn off the power 2 IGBT Check if the IGBT module is normal 3 Reboot the control box after 1 min If the error code still happens please exchan...

Страница 31: ...too high 3 If the voltage for power line is too high please wait for reboot before power line comes back to normal If not reboot the control box after 1 min 4 If the error code still happens please ex...

Страница 32: ...rr 8 Operation Box Communication Error 1 Turn off the power 2 CN703 Check the connection between operation box and control box CN703 3 Turn on the power again If the machine still cannot operate norma...

Страница 33: ...G 33...

Страница 34: ...lfunction on motor encoder board 3 Turn on the power again If the machine still cannot operate normally please contact with qualified technician Safety Switch Error When the motor rotating symbol stop...

Страница 35: ...G 35...

Страница 36: ...G 36 Simple Repair...

Страница 37: ...G 37...

Страница 38: ...G 38 Adjustment of Mechanism...

Страница 39: ...G 39...

Страница 40: ...G 40 Parts List...