1 - Device description 
 
2 - Operation 
 
3 - Mounting information 
 
4 - Trouble shooting 
 
5 - Security advice 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

SIROCO S.A.S. 

10 rue Jean Rostand - Z.I. 

BP 315 

69745 GENAS Cedex 

Tel: +33 (0)4 78 90 96 96 

Fax: +33 (0)4 78 90 15 98 

www.siroco.fr

 

Содержание ARIZONA

Страница 1: ... Ind B Page 1 of 6 ARIZONA 1 Device description 2 Operation 3 Mounting information 4 Trouble shooting 5 Security advice SIROCO S A S 10 rue Jean Rostand Z I BP 315 69745 GENAS Cedex Tel 33 0 4 78 90 96 96 Fax 33 0 4 78 90 15 98 www siroco fr ...

Страница 2: ...knob ARIZONA s front plate is available in different colors white grey anthracite or black Heater can be equipped with 600 400 or 300 blower that supplied in 12 V or 24 V with connections pipes diameters of 16 mm Product part numbers ARIZONA 600 ARIZONA 400 ARIZONA 300 Voltage Front plate color Part number Part number Part number White 0120 0001 0120 0101 0120 0201 Grey 0120 0002 0120 0102 0120 02...

Страница 3: ...d anticorrosive for copper and aluminum Use a cooling fluid officially recognize by automotive manufacturers Technical data Type Voltage Electrical power Weight Nominal air flow Heating capacity L depth see 3 step 2 ARIZONA 600 12 24 V 150 W 2 3 kg 380 m h 6 10 kW 227 mm ARIZONA 400 12 24 V 120 W 2 kg 285 m h 5 00 kW 218 mm ARIZONA 300 12 24 V 55 W 2 kg 200 m h 4 35 kW 218 mm Optimum heating capac...

Страница 4: ...ith 8 not supplied screws Blower motor axis should rather be in horizontal position on the vehicle Do not drill heater s body so as not to damage heat exchanger Connect water input and output by using cooling pipes with corresponding diameter Using suitable clamping rings Check for leaks in water Fixation stand 2 3 235 x 170 mm cut out 8 not supplied screws 8 Ø 3 7 mm Clamping rings Inlet pipe 3 3...

Страница 5: ... Replace cable Check for correct cable routing and connections according to the circuit diagram Electrical connections reversed Check connecting wires according to the circuit diagram and if necessary assemble correctly Blower switch defective Replace the switch with a new original component Blockage in fan unit Rectify cause of blockage e g object in impeller If necessary order new unit Blower no...

Страница 6: ... to the maximum Water flow rate through heat exchanger is too low Water lines kinked or squashed Relay hoses Water pump pressure too low see above for action Flush out water circuit Air in heat exchanger When the pumping pressure is sufficient the heater is self bleeding Install additional or more powerful water pump Unit is underdimensioned Install a more powerful unit Insufficient pumped water p...