26
A combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions
given in section 3 site requirements.
No purpose provided ventilation is normally required for this appliance.
The requirements of other appliances operating in the same space or room, and the results of a spillage
test must be taken into consideration when assessing ventilation requirements, this will have been carried
out by your Gas Safe registered installer.
For Republic of Ireland, ventilation may be required, see IS 813, ICP3, IS 327, and any other
rules in force.
OPERATING THE APPLIANCE (Remote control)
Note: Please ensure the sensor is in a position to be seen by your remote handset if this is not
in the correct position the fire will not operate correctly.
For your safety, the fire is fitted with a Flame Supervision Device (FSD), which will shut off the
Gas supply if for any reason the pilot is extinguished.
This device incorporates a fixed probe, which senses heat from the pilot burner flame, if the probe is
cooled, the device will prevent any gas flow.
If for any reason the flames go out or if the fire has been turned off for any reason, always
WAIT FOR
3 MINUTES
before attempting to re-light.
The pilot is visible through the Fuel bed at the front of the fire; rotate the coals for good
viewing
Fit the batteries (all components are to be found in the bag containing these instructions)
Fit the 9V battery in the hand set by pushing in the tab on the back of the hand set and pulling up, locate
the battery.
Fit the 6 AA batteries in the holder following the sequence as shown on the holder then attach to the cable
on the fire using the press connection and cover with the heat shield as described in Dia.8.
To light the fire, point the handset to the sensor on the front your fire.
Press and hold the two buttons together, on the left hand side of the handset.
The fire will give out a beep sound and you can release the
buttons.
After a few seconds you will hear the spark clicking spark to the
pilot light.
Once the pilot is lit the fires main burner will come on to the high
position (this whole process will take no more than 20 seconds).