24
Pilot flame shrinks when fire is on high
?
Fire smells when first lit or in use?
Poor gas flow to fire, check pressure with fire on high.
If pressure is low, remove any restriction in pipe work
or valve.
Check all isolators are adequately sized and fully open.
Check meter pressure is adequate.
Air leak under base of firebox, rectify.
Lint in pilot aeration hole, clean thoroughly internally.
Firebox grommet seal missing, rectify
Newness smell from brand new appliance.
Spillage occurring, the installer needs to carry out
spillage test and rectify any problems.
Low temperature sealants or combustible materials
used in incorrect positions.
Air leak under base of firebox, rectify.