23
SECTION 16: CLEANING THE CERAMICS
Remove the ceramic components.
Gently clean in the open air using a dry paint brush.
Be careful not to create dust from the coals.
Where necessary replace damaged components with genuine spares.
Seal scrap ceramic components in plastic bags and dispose at proper refuse sites as directed.
Re-fit the fuel bed by referring to the relevant sections of these instructions
.
SECTION 17: TROUBLESHOOTING GUIDE
Fire sparks but pilot Flame does not light?
A pilot lights, but then goes out before main burner lights?
Fire does not spark at pilot
?
Fire runs for a time and then cuts
off?
No gas to fire, check isolating valves are open.
Pipe work blockage, clean out.
Air not fully purged, re-purge supply, reset gap
correctly.
Blocked pilot, clean out internally.
Severe restriction in gas supply, clear obstruction.
Thermocouple not operating correctly check
connections.
Run through lighting system on the remote control
several times allowing the valve to rest each time.
HT lead detached, refit.
Spark gap too large or small reset correctly.
Spark shorting to metalwork under tray re-aligns HT
lead
Excessive room draught or flue pull, rectify.
Loose or faulty thermocouple, rectify.
O.D.S system in operation.
Firebox grommet seal not fitted, rectify.
Lint in pilot aeration hole, clean thoroughly internally