background image

 

19 

 

 

Section 10: OPERATING THE APPLIANCE  

(Remote control) 

 

See Section 18 Users Instructions  

 

 
 

Section 10.1: SPARK FAILURE 

The gap between the spark electrode and the pilot should be 3.5 - 4.5mm to produce a good 

spark. There should be no need to adjust this. 

 
If under any circumstances the electric spark fails, the pilot may be lit manually by 

proceeding with the ignition sequence as previously described, and after turning the control 
knob through the spark position, the knob should be held in and the pilot lit with a taper. 

 

 

SECTION 11: SETTING PRESSURE 

 

 

Remove the pressure test point sealing screw from the isolation elbow and attach a suitable pressure 

gauge. 

 

  

 

 

Check that the standing inlet gas pressure is at 20 mbar 

 

Light the pilot and check the correct operation of the burner at all the flame settings. 

 

Refer to the Operating instructions section 10.1 

 

Check that the inlet gas pressure is at 20 mbar when the fire is at its highest setting. 

 

Once the fire has been lit for 5 minutes, turn the gas OFF at the isolating elbow.  

Содержание SCENIC Edge

Страница 1: ...Frameless Lux and Edge Model options Remote Installation and User Instructions All instructions must be handed to user for safekeeping This is not a DIY product and must be installed by a Gas Safe registered installer Edition D 10 11 Country s of destination GB IE ...

Страница 2: ...Installation Requirements The appliance must be installed by a competent person in accordance with the Gas Safety Installation and Use Regulations 1998 A Gas Safety Registered installer must be used for this purpose Read all these instructions before any installation takes place and in conjunction with the appliance on site This appliance must be installed in accordance with the rules in force and...

Страница 3: ... the outer carton Check that the components supplied correlate with the component checklist below If for some reason any of the listed components are missing or damaged do NOT commence with this installation in doing so will invalidate your warranty Please dispose of all the packaging materials at your local recycling centre CONTENTS CHECK LIST Qty Description 1 Firebox and Burner Tray 1 Gather ho...

Страница 4: ...ing 12 13 14 7 2 Fitting the Burner Tray 15 8 Fuel Bed 19 20 21 9 Commissioning the Appliance 16 10 Operating the Appliance Remote Control 17 10 1 Spark Failure 18 11 Setting Pressure 18 12 Spillage Monitoring System 19 13 Testing for Spillage 20 14 Briefing the Customer 21 15 Servicing 22 16 Cleaning the Ceramics 23 17 Troubleshooting Guide 23 24 18 User Instructions 25 28 19 Warranty Details 29 ...

Страница 5: ...nd Consolidation Regulations issued by the Scottish Development Department BS 1251 BS 4543 part2 BS 5440 parts 1 2 BS 5871 part 3 BS 6461 parts 1 2 BS 6891 BS 8303 Failure to comply with these regulations could lead to prosecution and deem the warranty Invalid This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space Consult all instruc...

Страница 6: ... that leakage is not evident at any joints Repair and re test as necessary before the appliance is installed Any flue box used must be installed onto a suitable non combustible insulating surface at least 12mm thick covering the entire base area of the box The flue must have an effective height of at least three metres as measured from the top of the appliance to the top of the flue Any flue dampe...

Страница 7: ... Gas Inlet connection 8mm Compression 8mm Compression 8mm Compression Overall Height 610mm 588mm 654mm Overall Width 525mm 722mm 1121mm Overall Depth 274mm 310mm 330mm Recess Height 552mm 552mm 613mm Recess Width 405mm 605mm 1015mm Recess Depth 270mm 305mm 325mm Air Vent N A N A Yes Pilot Assembly Thermocouple Oxy pilot NG 84009079000 Oxy pilot NG 84009079000 Oxy pilot NG 84009079000 Valve ACS LP ...

Страница 8: ...me Safety Device FSD may occur Spillage detected during commissioning is almost always a result of poor flue performance that cannot be corrected by any amount of ventilation For Republic of Ireland ventilation may be required see IS 813 ICP3 IS 327 and any other rules in force Section 5 SITE REQUIREMENTS The fireplace opening should be inspected and repairs made where necessary This appliance req...

Страница 9: ...and embossed paper positioned too close to the appliance may discolour or scorch 400 MM 600 MM 1000 MM A Width 420mm A Width 625mm A Width 1025mm B Height 560mm B Height 583mm B Height 622mm C Depth 280mm C Depth 310mm C Depth 330mm D From Floor 300 450mm D From Floor 300 450mm D From Floor 300 450mm Note always check to ensure there is enough room to fit the gather hood that comes with all 600 an...

Страница 10: ...m must be clad with a non combustible board The correct clearances to combustible materials i e false chimney breast etc must be adhered to The manufacturer of the prefabricated box s instructions for fitting the prefabricated box must be complied with at all times Please ensure the firebox does not obscure the flue box outlet Flue Adaptor for 600 and 1000 Models Optional Extra Gather hood comes w...

Страница 11: ...Section 7 INSTALLATION OF APPLIANCE Always ensure that the gas supply is isolated before commencing installation of the appliance The fireplace opening and environment must be in compliance with specifications laid down in the appropriate sections of these instructions Remove the appliance from its carton as described previously and stand on a dust sheet Place the fuel bed ceramics and fixings saf...

Страница 12: ...e then care is needed when removing the burner not to damage the wiring system of the fire you will need to remove the connections to the control box from the valve thermocouple and spark generator lead Battery pack and Sensor connections Gas Valve Connections Thermocouple Connections Spark Generator Lead Connections ...

Страница 13: ...y removing the three screws holding the inspection cover over the isolation valve and undo the connecting nut to the isolation tap Remove the four screws two on each side of the burner tray and undoing the connecting nut to the isolation tap Remove the two burner screws as shown ...

Страница 14: ... that the base is level At this stage it is essential to ensure that the gather hood outlet of the fire is not obstructed in any way The gather hood is an integral component for the correct function of the appliance and will invalidate the warranty if the gather hood is not fitted Remove the fire box and apply the self adhesive sealing strips around the edge of the rear of the firebox frame approx...

Страница 15: ...o the incoming supply to facilitate servicing The gas pipe must be suitably protected where it passes through fireplace openings Any sleeving should be sealed to the pipe at its ends The open end of the gas supply pipe should be temporarily sealed to prevent ingress of dust and dirt during installation Note DO NOT install or use the appliance without this seal in place Failure to fit this seal cor...

Страница 16: ...a finish ready to be decorated SECTION 7 2 FITTING THE BURNER TRAY Temporarily fit the burner tray and ensure a suitable gas route can be achieved This process is a simple reverse of the previous instructions on how to remove the burner tray On the remote version please take care not to pull or overstretch the electrical connections as this may cause the fire to fail on commissioning 600 and 1000 ...

Страница 17: ...17 400 Models SECTION 8 FUEL BED LAYOUT Place the filtration granules the smaller ones supplied in to the channel levelling out the granules equally ...

Страница 18: ... the pilot assembly Leave the area around the pilot assembly clear to allow for good cross lighting Place any further pebbles or twigs over the chippings to the desired look Section 9 COMMISSIONING THE APPLIANCE Turn on and test the gas supply up to the fire for any leaks in accordance with current Approved Codes of Practice ACOPs ...

Страница 19: ...urning the control knob through the spark position the knob should be held in and the pilot lit with a taper SECTION 11 SETTING PRESSURE Remove the pressure test point sealing screw from the isolation elbow and attach a suitable pressure gauge Check that the standing inlet gas pressure is at 20 mbar Light the pilot and check the correct operation of the burner at all the flame settings Refer to th...

Страница 20: ...d again recalls your installer to check and rectify any problem The thermocouple connection into the back of the gas control valve may also have worked loose during installation simply get the installer to tighten If pilot disturbance is not the cause then the ODS safety system may be in operation Switch the appliance OFF check the flue and carry out any remedial work required Relight the fire and...

Страница 21: ...ctions must be handed to the user for safekeeping Show the customer how to light and operate the fire After commissioning the appliance the customer should be instructed on the safe use of the appliance and the informed for the need of regular servicing Frequency of service depends on usage but MUST be carried out at least once annually Cleaning of the fire may be achieved when the fire is cold us...

Страница 22: ...ve the two screws that retain the access plate and remove cover to allow access to the isolation tap turn off the gas at this valve and disconnect the burner tray 4 Remove the four screws that retain the burner tray in place and gentle lift out careful to disconnect all electrical components 5 Check the firebox opening for debris and dust and remove 6 Check the flue with smoke pellet for correct o...

Страница 23: ...rk at pilot Fire runs for a time and then cuts off No gas to fire check isolating valves are open Pipe work blockage clean out Air not fully purged re purge supply reset gap correctly Blocked pilot clean out internally Severe restriction in gas supply clear obstruction Thermocouple not operating correctly check connections Run through lighting system on the remote control several times allowing th...

Страница 24: ...y sized and fully open Check meter pressure is adequate Air leak under base of firebox rectify Lint in pilot aeration hole clean thoroughly internally Firebox grommet seal missing rectify Newness smell from brand new appliance Spillage occurring the installer needs to carry out spillage test and rectify any problems Low temperature sealants or combustible materials used in incorrect positions Air ...

Страница 25: ...recommended that a suitable fire guard conforming to BS 6778 is used especially where young children the elderly or infirm are concerned Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper may discolour if fitted too close to the fire See relevant section for further details on clearances to combustibles No combustible material or flooring...

Страница 26: ... heat from the pilot burner flame if the probe is cooled the device will prevent any gas flow If for any reason the flames go out or if the fire has been turned off for any reason always WAIT FOR 3 MINUTES before attempting to re light The pilot is visible through the Fuel bed at the front of the fire rotate the coals for good viewing Fit the batteries all components are to be found in the bag con...

Страница 27: ...default setting 6 Remote Control fires will need 6 x AA batteries Good quality alkaline battery maybe used or Lithium type batteries can be used To turn down the fire point the handset to the sensor on your fire then push and hold the minus button small flame if you release immediately the flame will go to low if you keep holding the flame will lower slowly and you can release the button to your d...

Страница 28: ...aired by a competent person and the fire serviced before further use PAINTED AREAS These can be cleaned using a dry cloth COALS AND CERAMICS See the relevant section in the Installation Guide of these instructions SERVICING The fire and flue should be checked on an annual basis to ensure all of the products of combustion are entering the flue and that there is no excessive build up of soot The fre...

Страница 29: ...and are mostly dealt with in the installation instructions DO NOT USE YOUR APPLIANCE and in the first instance contact your installer to investigate these further to establish their cause before contacting Sirocco CONTACTING SIROCCO FOR WARRANTY SERVICE OR TO PURCHASE SPARE PARTS In the event of a service or parts claim please note that some parts such as ceramics batteries trims and fronts etc ar...

Страница 30: ...30 SECTION 20 LIST OF SPARES 400 models ...

Страница 31: ...31 Royal 600 Remote Control ...

Страница 32: ...32 Royal 1000 Remote Control ...

Страница 33: ...33 400 Ceramics 600 Ceramics 1000 Ceramics ...

Страница 34: ... REMOTE VAL TU ROYS 4 SI 2 A2 PILOT GAS TUBE 4MM REMOTE VAL TU ROYS 4 SI 3 A 3 VALVE BURNER TUBE 8MM REMOTE VAL TU ROYS 4 SI 4 4 A BURNER TUBE REMOTE VAL TU ROYS 4 SI 1 600 MODEL CODE SPARE PART DESCRIPTION PARTNUMBER 1 F GRAVEL GREY ROYAL 600 CER G ROY 6 GRY GRAVEL BLACK ROYAL 600 CER G ROY 6 BLK 2 F BURNER GRANUALS CER GRT ROY 6 GRY 1B ENGINE EXCLUDING CERAMICS ROYS 6 N RC ENGINE 2E RECEIVER VAL...

Страница 35: ...LVE VAL RC UN VAL SIT 6 10E BATTERY LEAD VAL RC UN BL SIT 7 11E BATTERY HOLDER VAL RC UN BH BCL 0 12E PILOT REMOTE NG VAL RC UN PL SIT 8 1 A GAS INLET TUBE 8MM REMOTE VAL TU ROYS 10 SI 2 A2 PILOT GAS TUBE 4MM REMOTE VAL TU ROYS 10 SI 3 A 3 VALVE BURNER TUBE 8MM REMOTE VAL TU ROYS 10 SI 4 4 A BURNER TUBE REMOTE VAL TU ROYS 10 SI 1 SPARE PARTS If you need assistance or wish to purchase spare parts 0...

Страница 36: ... siroccofires com Nad Lasem 8 Zabia Wola 96 321 Zelechow Poland TECHNICAL HELP LINE Speak to a Sirocco trained engineer 0904 084 3473 0904 084 FIRE This is a premium rate number charged at 1 00 plus vat per minute from BT lines Mon to Fri 9 00 to 17 00 WARRANTY AND SERVICE For warranty registration or for a home service call www siroccofires com For assistance to complete a registration or a home ...

Страница 37: ...le is made through an approved company stockist 10 Any installation labour transportation or other related costs expenses arising from defective parts rapier replacement or otherwise of same will not be covered by this guarantee nor shall the company assume responsibility for same Furthermore the company shall not be responsible for any indirect or consequential damages except as provided by law 1...

Страница 38: ... parts found to be defective in material or workmanship only after confirmation of the defect by a Sirocco engineer or an appointed Sirocco engineer provided that such parts have been subject to normal conditions of use 28 Any installation labour transportation or any other related or expenses arising from defective parts repair or otherwise of the same are not covered by this warranty nor shall S...

Отзывы: