Section 10: OPERATING THE APPLIANCE
(Remote control)
See Section 18 Users Instructions
Section 10.1: SPARK FAILURE
The gap between the spark electrode and the pilot should be 3.5 - 4.5mm to produce a good
spark. There should be no need to adjust this.
If under any circumstances the electric spark fails, the pilot may be lit manually by
proceeding with the ignition sequence as previously described, and after turning the control
knob through the spark position, the knob should be held in and the pilot lit with a taper.
SECTION 11: SETTING PRESSURE
Remove the pressure test point sealing screw from the isolation elbow and attach a suitable pressure
gauge.
Check that the standing inlet gas pressure is at 20 mbar
Light the pilot and check the correct operation of the burner at all the flame settings.
Refer to the Operating instructions section 10.1
Check that the inlet gas pressure is at 20 mbar when the fire is at its highest setting.
Once the fire has been lit for 5 minutes, turn the gas OFF at the isolating elbow.