11
It is important that the sealing requirements of the appliance are met at all times and that
the flue box is sealed to any back or infill panel.
Section 6: DEBRIS SPACE
In accordance with BS 5871 part 2, minimum debris collection volumes are required
behind the installed appliance.
CLAY/CEMENT LINES OR BLOCK FLUE WHICH IS NEW, UNUSED, OR PREVIOUSLY
ONLY USED WITH A GAS FIRE.
Appliance recessed depth + 20mm
UNLINED FLUE OR CHIMNEY WHICH HAS BEEN PREVIOUSLY USED FOR A SOLID
FUEL OR OIL BURNING APPLIANCE
Appliance recessed depth + 60mm
Section 7: INSTALLATION OF APPLIANCE
Always ensure that the gas supply is isolated before commencing installation of the appliance.
The fireplace opening and environment must be in compliance with specifications laid down in
the appropriate sections of these instructions.
Remove the appliance from its carton as described previously and stand on a dust sheet.
Place the fuel bed, ceramics and fixings safely to one side.
Removing the burner 600 and 1000 Models.
Remove the burner from the assembly by removing the two screws holding the inspection
cover over the isolation valve, and undo the connecting nut to the isolation tap.
Remove the four screws two on each side of the burner tray and undoing the connecting nut
to the isolation tap.