Device
Page 47
Note:
Version, IP Address, and Port are required fields.
4
In the
Alternate IP Address
box, if desired, type an alternative destination IP address.
5
In the
Alternate Port
box, if desired, type an alternative destination port number.
6
If desired, select
Enable
to activate
Authentication trap
.
This adds an authentication trap to catch attempts at access using the wrong community
string.
Agent
The unit has an SNMP agent running which listens for information requests from the SNMP
manager on port 161 by default.
9.7
Heater
The heater prevents condensation of the camera window.
Mode
You can set the heater on, off or to automatic mode. By default, the heater is set to automatic
mode.
Temperature threshold
Drag the Temperature threshold slider to set the temperature threshold. By default, the
threshold is set to 10
0
C. If the temperature drops below this threshold, the camera heater will
switch on.
Heater state
Indicates whether the heater is on or off. If the heater state indicates a power error, it means
that the device is not properly powered. See also Troubleshooting (on page 61).