4
4.2
Safety rules for personal protection
Persons with pacemakers or other metal or electronic surgical implants must not
operate with the 06434 and must keep a safe distance of at least 1m from the device.
When working with 06434 do not wear any metal objects such as jewelry, rings,
watches, necklaces, identification tags, belt buckles, piercing and even clothing with
metal parts such as metal rivets, buttons and zippers, etc. - 06434 can heat up these
metal objects quickly and cause serious burns or clothing ignition.
ATTENTION: Coil applicator and heated object can reach high temperatures and
cause burns or cause a fire.
When using the 06434 always wear safety goggles or face shield.
When using the 06434 hazardous fumes may be produced by burning old paint,
lubricants, sealants, adhesives, etc. These exhalations can be toxic. Always wear
appropriate protective masks or respirators.
When working with the 06434 always wear protective gloves with corresponding
thermal resistance. High temperatures generated by the use of 06434 may cause
serious burns in the case of touching the heated part.
Always keep proper footing and balance for safe control of the 06434 even in unexpected situations.
Do not use the 06434 near any device with pyrotechnics (e.g. airbag). The resulting heat can cause
their unexpected explosion. Keep a minimum distance of 10-20 cm from these devices.
4.3
Electrical safety rules
This is a safety Class I device, which may be supplied with power only from the
power outlet with a protective conductor,
which must be connected to the device as
first and in any case must not be interrupted (e.g. by an extension cord). Any
interruption of the protective earth conductor, or its disconnection will cause a
potential electric shock hazard that can cause injury. Make sure that the device
(device chassis) is properly grounded.
Do not twist or sharply bend the power cord, as it may damage the internal wiring.
Never use 06434 if the power cord shows any signs of damage. Keep the power cord
away from heat, oil, sharp edges or moving parts. Never repair the power cord – if
damaged, the power cord must be replaced. Damaged cords create a risk of electric
shock.
Содержание 06434
Страница 1: ...Heat Induction Tool 06434 Instructions for use and Maintenance...
Страница 19: ...19...
Страница 20: ...20...