Sinergex Nitro 6000 Скачать руководство пользователя страница 1

 
 
 
 

 

   

6000 

Digital Intelligent Battery Charger 

 

OPERATOR’S MANUAL 

                   

 

 
 
 
 
 
 
 

TM 

Содержание Nitro 6000

Страница 1: ...6000 Digital Intelligent Battery Charger OPERATOR S MANUAL 1 TM ...

Страница 2: ...ttery and the area should be kept well ventilated Because of this risk of explosive gas only connect and disconnect the battery leads when the mains supply is disconnected BATTERY TYPES This charger is only suitable for normal lead acid AGM Gel batteries and should not be used to recharge NICAD or any other type of battery PLEASE NOTE When not in use store the charger in a dry area to avoid damage...

Страница 3: ...harge a frozen battery If battery fluid electrolyte becomes frozen bring battery into a warm area to allow battery to thaw before you begin charging Do not touch the DC battery clamps together when the charger is on Never operate charger if it has received a hard blow been dropped or otherwise damaged Take it to a qualified professional for inspection and repair Be sure to position the charger pow...

Страница 4: ...d acid battery A lead acid battery can produces a short circuit current high enough to weld a ring or the like to metal causing severe burns INTRODUCTION The Sinergex Nitro 6000 is member of the family of advanced battery chargers manufactured by Sinergex Technologies Nitro chargers will increase your battery s performance and prolong its life Please carefully read and follow the following safety ...

Страница 5: ...majority of its charge During this stage the battery brought to 75 80 of its charger The NITRO charger delivers maximum current until the terminal voltage has risen to the set level of 14 4 V for Normal battery selection and 14 2 V for Gel battery selection Absorption Completes the charge up to virtually 100 at a constant voltage of 14 4 V at 25 C The current tapers off after the current reached t...

Страница 6: ...The Nitro 6000 compensates for this drop and automatically adjusts to maximize the charge being delivered to your battery REVERSE POLARITY PROTECTION The Nitro 6000 has built in Reverse Polarity Protection Reverse Polarity occurs when connecting the Positive or Red DC cable to the Negative or Black battery terminal The REVERSE LED on the front Touch Panel will illuminate and charging will not star...

Страница 7: ... OTHER FEATURES Anti Spark Protection Short Circuit Protection Battery and Charger Overheating Protection Waterproof ABS Housing Ingress Protection Rating IP20 TOUCH PANEL INDICATORS REVERSE Reverse Polarity FAULT Battery Fault ON Charger is Connected to AC Power CHARGING Battery Charger is Charging BATTERY CHARGED Battery if Fully Charger and is now in Float Mode GENERAL SAFETY PRECAUTIONS AND PR...

Страница 8: ...in to an earthed AC outlet If the battery needs to be removed from the vehicle before charging always remove the grounded terminal from the battery first Also ensure that all accessories in the vehicle are turned off to prevent arcing Ensure the battery terminals are clean Always refer to the manufacturer s instructions regarding charging and charging rates and battery maintenance OPERATION The Ni...

Страница 9: ...ry N or It is important to ensure that both DC clamps are secure with their respective terminal posts Connect the charger s AC power cable to an AC power outlet Once you have connected the Nitro 6000 to AC power it will sound a tone for 0 5 seconds and the Simple Touch power panel LEDs light for two seconds The battery charger is now in the Standby operating mode and the 6 Amp GEL and ON LEDs are ...

Страница 10: ...g is completed disconnect power cable from the AC power and disconnect cables and clamps in reverse order from which they were connected If using the Nitro for maintenance charging leave charger connected to the battery and the Nitro will keep your battery at the optimum level of charge 2 TROUBLE SHOOTING INCORRECT CONNECTION REVERSE POLARITY If the DC battery clamps are connected incorrectly to t...

Страница 11: ...y and follow the OPERATION steps as described in P 8 BATTERY FAULT A few seconds after switching THE Nitro 6000 on the LED indicator FAULT will illuminate if the following occurs A Low battery voltage 3 V B High battery voltage 15 V 12 V battery C Battery short circuit or battery cell short circuit Under these conditions the battery charger will stop charging In the event of A B or C the battery m...

Страница 12: ...to the AC power supply CHARGING TIME The table below is a guide to the typical charge time for different batter sizes of 12 V 6 Cell batteries Battery Size Charging Time 20Ah 6 hours 24Ah 7 hours 30Ah 9 hours 36Ah 10 hours 44Ah 13 hours 55Ah 16 hours 75Ah 20 hours Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your local au...

Страница 13: ...gether with your proof of purchase The warranty is void if the product has been damaged or not used as described in this manual Warranty is void if a non authorized repair has been performed Sinergex Technologies makes no other warranty expressed or implied Sinergex Technologies is only responsible for repair or replacement at Sinergex Technologies Discretion of the defective product and is not re...

Отзывы: