User Manual of EM730/EM730E Series Inverter
153
function status is dependent on the “OR logic” of the two terminals. In the case of F02.00=1 and
F02.04=1, once one of the terminals X1 or X5 is valid, the “RUN” function of the inverter will
be enabled.
Table 7-6 Function List of Multi-function Digital Input Terminals
Settings
Function
Description
0
No function
Disable the protection terminal or set it to “0: Unavailable” to
prevent malfunction.
1
Running terminal
(RUN)
When the command source is set to terminal control
(F00.02=1), and the function terminal is valid, the inverter will
execute the corresponding RUN function according to the set
value of the terminal control mode option (F00.03). (See the
explanation of the function code F00.03 for details.)
2
Running direction
F/R
When the command source is set to terminal control
(F00.02=1), and the function terminal is valid, the inverter will
execute the corresponding F/R function according to the set
value of the terminal control mode option (F00.03). (See the
explanation of the function code F00.03 for details.)
3
Stop control of
three-line operation
When the command source is set to terminal control
(F00.02=1), the terminal control mode is set to three-line
control (F00.03=2/3) and the function terminal is valid, the
inverter will execute the stop command. (See the explanation of
the function code F00.03 for details.)
4
Forward jog (FJOG)
When the command source is set to terminal control
(F00.02=1), and the function terminal FJOG is valid, the
inverter will run forward; if the function terminal RJOG is
valid, the inverter will run reversely; and if the two function
terminals are valid at the same time, the inverter will decelerate
to stop.
★:
When reverse running is prohibited, the reverse jog will be
invalid.
5
Reverse jog (RJOG)
6
Terminal UP
If the function terminal UP is valid, the frequency offset will be
increase at the rate defined by F12.11; and if the function
terminal DOWN is valid, the frequency offset will decrease at
the rate defined by F12.11.
If the UP/DOWN offset clear terminal is valid, the frequency
offset will be cleared to 0.
Final set frequency of the frequency source A = set frequency
of the frequency source A + UP/DOWN offset.
★
: The UP/DOWN function is valid only when the main
frequency source A is involved in setting.
The offset frequency can be viewed via F18.15.
The function of the terminal UP/DOWN is the same as that of
7
Terminal DOWN
8
Clear UP/DOWN
offset