1. Normal cutting model
2. Current parameter display area
3. Perforated cutting model
4. Post flow display area
5. The regulating current is the display area(Press
the knob to switch between 5 and 6)
6. The regulating Post flow is the display area(Press
the knob to switch between 5 and 6)
7. Barometric display area
8. Select mode button
9. Parameter setting knob
Compressed Air Testing/Setting button (8)
Long press button(8) for 2 seconds to enter the check
gas, and the display screen will display the above in-
terface.
When positioned as ‘set’ compressed air control valve
is open continuously. This is useful for testing and
setting the air pressure without having to activate
the trigger circuit. ‘Run’ position is normal operation.
AIR Error Display (1)
2
4
3
1
The above interface is displayed when the machine
has no gas input or the air pressure is low.
6. MACHINE USE
6.1. MACHINE LAYOUT DESCRIPTION
6.1.1. Layout for the front and rear panel
1. Plasma Torch Euro/ Central Connector.
2. CNC Interface Connection
3. Earth Lead Connection Socket.
4. Air Filter Condensate Drain Tube.
5. Air Pressure Regulator Outlet Pressure Gauge.
6. Air Pressure Regulator Knob.
7. Compressed Air Inlet.
8. Input Power Cable.
9. Power Switch: Turn on or off the power source.
10. Air Condensate Filter/Trap Bowl.
6.1.2. Further Controls Explained
Main interface description
2
8
3
1
4
7
9
5
6
1.995.232 EN - Rev. 1.1
NOVACUT 106 LCD
21