2
1.3 Product Features
1.3.1 General
It’s a kind of integrated DC inverter unit that comprises cooling, heating and water heating functions, and up to 5.0
energy efficiency. It adopts R32 refrigerant and two-stage compressor. For heating, ambient temperature range is
-25~35°C while the leaving water temperature range is 20~60°C.
The S therm unit is designed specially for the European market where there is a demand for high-temperature
water. Thanks to the dual-stage compression and enthalpy gain through gas injection, the heating energy
efficiency at low temperature will rise up greatly with the leaving water temperature up to 60°C. The whole series
of products strictly comply with EN14511,EUROVENT energy efficiency Class A and SCOP class A+++(35°C),
SCOP class A++(55°C) with EN14825. Their COP can reach up to 5.0. This unit can realize space heating and
sanitary hot water supply through terminal units, like the fan coil unit, floor coil and radiator. Environment-friendly
refrigerant R32 is adopted for the unit, with ODP of 0 and quite low GWP (=675). Besides, the adopted heat pump
technologies will reduce consumption of coal and other energy source and lower greatly CO
2
emission. Ranged
from 4.0kW~9.5kW, it is widely applicable to small and medium-sized apartment, large-sized villa etc.
1.3.2 Features
◆
Wide Operation Range
Heating: -25~35°C; Cooling: 10~48°C; Water Heating: -25~45°C
◆
Unique Low-Temp Hi-heat Dual-stage Compressor
(1) Under low-temperature conditions, compared with the conventional compressor, the dual-stage low-temp
hi-heat compressor will generate less loss of heat capacity and get higher energy efficiency.
(2) Floodback, high discharge temperature and other problems can be completely avoided under low-temp
conditions and the compressor’s reliability will be enhanced greatly.
(3) Dual-stage compression, dual-stage throttling and intermediate enthalpy adding through gas injection will
raise the leaving water temperature and improve the control accuracy.
(4) Values of resistance to compressor status:
4/6kW——UV/VW/UW:1.67±7%Ω
8/10kW——UV/VW/UW:0.99±7%Ω
◆
High-efficiency Component(Inverter pump, Inverter fan, Plate heat exchanger)
(1) The A-class high-efficiency inverter water pump which complies with the European ErP directive, can
control the running frequency based on the actual load. Therefore, it can enhance the operation efficiency
and control the water temperature more accurately.
(2) The DC inverter fan can control the air volume accuratately and make the system run more stably and save
more energy.
(3) The high-efficiency plate heat exchaner will improve the unit’s performance largely.
Содержание GSH ERB-3 Series
Страница 1: ...GSH XXXTRB2 GSH XXXERB2 GSH XXXTRB2 3 GSH XXXERB 3 SPLIT HEAT PUMPS SERVICE MANUAL H E A T P U M P S...
Страница 44: ...40 7 GSH 80ERB2 GSH 100ERB2...
Страница 48: ...44 Parts List of GSH 120ERB GSH 140ERB GSH 160ERB 9 GSH 120ERB GSH 140ERB GSH 160ERB...
Страница 53: ...49 12 GSH 120TRB2 3 GSH 140TRB2 3 GSH 160TRB2 3...
Страница 55: ...51 13 GSH 120ERB 3 GSH 140ERB 3 GSH 160ERB 3 Parts List of GSH 120ERB 3 GSH 140ERB 3 GSH 160ERB 3...
Страница 108: ...104 3 3 3 2 Help Click Help and view the operation instructions of the APP...
Страница 109: ...105 3 3 3 Feedback Click Feedback to submit feedback...
Страница 116: ...112 3 GSH 40ERB2 GSH 60ERB2 4 GSH 80ERB2 GSH 100ERB2...
Страница 131: ...127 GSH 80ERB GSH 100ERB GSH 40ERB2 GSH 60ERB2...
Страница 133: ...129 GSH 120ERB 3 GSH 140ERB 3 GSH 160ERB 3 GSH 120ERB GSH 140ERB GSH 160ERB...
Страница 134: ...130 4 9 Wiring of the Terminal Board GSH 40TRB GSH 60TRB GSH 80TRB GSH 100TRB...