Sinclair ARCTIC Series Скачать руководство пользователя страница 1

              ARCTIC SERIES

              

                  outdoor unit

 

            ASH-13AIA PT, ASH-18AIA PT            

 

USER'S MANUAL 

Содержание ARCTIC Series

Страница 1: ...ARCTIC SERIES outdoor unit ASH 13AIA PT ASH 18AIA PT USER S MANUAL ...

Страница 2: ... Original instruction ...

Страница 3: ...ppliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Do not wash the air conditioner with water to avoid electric ...

Страница 4: ...damage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not spill water on the remote controller otherwise the electric shock or damage Please contact dealer when you need to repair air conditioner Do not repair air conditioner by yourself It may cause object...

Страница 5: ...bles before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Properly connect the live wire neutral wire and any work related to electricity and safety Be sure to cut off the power supply before proceeding Including an circuit break with suitable capacity please...

Страница 6: ...onnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only Precautions WARNING wire which can t be used for other purposes The grounding resistance should comply with national electric safety regulations The air conditioner is the first class electric appliance It keep the interconnection cable away from the copper tube The temperature of refrige...

Страница 7: ...st be installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for children and For the air conditioner with plug the plug should be Working temperature range NOTICE Indoor side DB WB C Outdoor side DB WB C Maximum cooling 32 23 54 26 Maximum heating 27 24 18 The operating temperature range outdoor temperature for cooling is 18 54 The oper...

Страница 8: ...air inlet air outlet Connection wire Parts name Outdoor Unit NOTICE Actual product may be different from above graphics please refer to actual products 7 ...

Страница 9: ...nsion diagram Drainage pipe At least 50cm At least 50cm At least 30cm At least 200cm Space to the obstruction Space to the obstruction Space to the obstruction Space to the obstruction At least 30cm Space to the wall 8 ...

Страница 10: ...not affect neighborhood 2 The location should be well ventilated and dry in which the outdoor unit Tools for installation 1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note Please contact the local agent for ins...

Страница 11: ...pliance shall be installed in accordance with national wiring regulations grounding with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock 2 The yellow green wire in air conditioner is grounding wire which can t be used for other purposes 3 The grounding resistance should comply with national electric safety regu...

Страница 12: ...least 3cm above the floor in order to install drain joint For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacity of 10000W 16000W 10 expansion screws are needed Step two install drain joint Only for cooling and heating unit 1 Connect the outdoor drain joint in...

Страница 13: ...Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe 3 Pretightening the union nut with hand 4 Tighten the union nut with torque wrench by referring to the sheet below handle screw gas pipe liquid pipe liquid valve gas valve union nut pipe joint Hex nut diameter Tightening torque N m Φ 6 Φ 9 52 Φ 12 Φ 16 Φ 19 30 40 45 55 60 65 70 75 15 20 Indoor unit connection 18K POWER N...

Страница 14: ...lightly dow nwards The drain hose can t be curved raised and fluctuant etc The water outlet can t be placed in water in order to drain smoothly Installation of outdoor unit U shaped curve wall drain hose the drain hose can t raise upwards The drain hose can t be fluctuant The drain hose can t be fluctuant The water outlet can t be fluctuant The water outlet can t be placed in water Note 2 Fix the ...

Страница 15: ...ant charging vent 2 Connect the charging hose of piezometer to the refri gerant charging vent of gas valve and then connect the other charging hose to the vacuum pump 3 Open the piezometer com pletely and operate for 10 15min to check if the pressure of piezometer re mains in 0 1MPa 4 Close the vacuum pump and maintain this status for 1 2min to check if the pres sure of piezometer remains in 0 1MP...

Страница 16: ...it grounded securely It may cause electric leakage Does the power cord follow the speci fication It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet It may cause insufficient cooling heating capacity The dust and sundries caused during installation are removed It may cause malfunction or damaging the parts The gas valve and liquid valve of connection...

Страница 17: ...refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter Cooling capacity Cooling capacity 5000Btu h 1465W 24000Btu h 7032W 7000Btu h 2051W 28000Btu h 8204W 9000Btu h 2637W 36000Btu h 10548W 12000Btu h 3516W 42000Btu h 12...

Страница 18: ...ction pipe Liquid pipe mm Gas pipe mm Φ6 Φ6 or Φ9 52 Φ12 Φ16 Φ19 Φ22 2 Φ9 52 or Φ12 Φ16 or Φ19 Φ19 or Φ22 2 Φ25 4 or Φ31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350 120 120 50 20 Outdoor unit throttle Configuration of connection pipe 17 ...

Страница 19: ...itable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the port with expander Note A is different according to the diameter please refer to the sheet below expander hard mold pipe F Inspection Check the quality of expanding port If there is any blemish expand the p...

Страница 20: ...19 ELECTRIC SCHEMATIC DIAGRAM ASH 13AIA PT outdoor ASH 18AIA PT outdoor ...

Страница 21: ...20 RATING LABEL ...

Страница 22: ...21 ENERGY LABEL ...

Страница 23: ...is located INFORMATION CONCERNING USED REFRIGERANT MEDIUM This unit is containing fluorinated gases included in the Kyoto protocol The maintanance and the liquidation must be carried out by qualified personel Type of refrigerant R410A The composition of the cooling medium R410A 50 HFC 32 50 HFC 125 The quantity of the refrigerant please see the unit label The value GWP 2088 GWP Global Warming Pote...

Отзывы: