Installation
20222246 / Rev. A
13
3.2
QS50 connection
The QS50 is supplied with 10 m (33’) cable with one open end.
The QS50 is hard wired to the autopilot junction unit. Strip about
25 mm (1’) of the cable insulation and pull the shield backwards.
Secure the cable the same way as the other cables in the junction
unit and connect the wires in parallel with the cable shown on
Figure 3-1 using the same color code.
Figure 3-1 QS50 connection
Alternatively, a Robnet male connector (P/N 44160844) can be
mounted to the cable and plugged directly into the autopilot
control unit or any other device in the system containing a
Robnet connector. Refer to Figure 3-2 for pin configuration and
color code of the network cable.
Cable
pairs
Color
code
Pin Signal
1
st
pair Pink
5
V
Grey
4
V
SYSTEM–
2
nd
pair Brown
1
Bus–
5
4
2
1
6
FRONT VIEW
3
White
2
Bus+
Figure 3-2 Robnet Plug Pin Configuration