Page 32
MARIS ECDIS900 Installation Manual
N
AVTEX
Connect the Navtex receiver data output (not printer output) to SIS4000-Mk2. It is common
practice to connect to the monitoring computer, but very often it is easier to connect to the
planning computer at the chart table.
Reset the Navtex receiver to factory defaults. Set up the Navtex receiver to receive all
messages from all stations and to send everything to the data output port.
The ECDIS900 computer that is physically connected to the Navtex receiver runs as the
Navtex Master. Install Navtex Server and Navtex Inbox software on that computer. Accept
default settings but select NMEA extension.
The other computers in the network run as Navtex Slaves.
Install Inbox only, do NOT install the Server. Accept default settings but select NMEA
extension.
Restart and verify the Sensor Monitor and ECDIS900 are running.
NAVTEX MASTER CONFIGURATION
1.
On the desktop’s process line, right-click the server icon and then click “Open Server
Dialog”.
2.
The server is running. Click “Options/Port Settings”. Select “Network” and enter the
SIS4000-Mk2 Navtex sensor port to where the Navtex receiver is physically connected.
3.
Select “Options”.
Verify that “Use NMEA Extensions” is ticked on.
Remove all other tick marks and check that something is rolling in.
This depends on the receiver in use, these examples are from a JRC NCR333:
$CRALR, (list of possible errors - normally flagged V for not active).
$CRNRX, (list of received messages, line by line).
BLABLABLA…, (message in plain text).
If the message is corrupted, the signal is inverted. Swap the wires. The data must be
clearly readable and in plain text.
Look for the NRX message. This is needed to continue.
If NRX messages are correct, turn off the terminal window by clicking “Options/Pause”.
4.
Click “Options/Position Settings”.
Select “Accept the Position From Sensor Monitor”. Click “Ok”. Note that the Server title
bar has changed, and now shows you’re the current position and NAVTEX area.
5.
Click “Options/Expiry”.
Select “Enable Auto Check” and set it to 3 days.
6.
Make sure the server is running by clicking “Actions” and verify that you have a tick
mark at “Start”. Then minimize the server.
This concludes the server setup.
Содержание Maris ECDIS900
Страница 1: ...ENGLISH Maris ECDIS900System Installation Manual www navico commercial com ...
Страница 40: ...Page 40 MARIS ECDIS900 Installation Manual ECDISMK15 MECHANICAL DRAWINGS ...
Страница 41: ...Page 41 MARIS ECDIS900 Installation Manual DIMENSIONAL DRAWINGS FOR 19 TERMINAL LAYOUT FOR 19 ...
Страница 42: ...Page 42 MARIS ECDIS900 Installation Manual DIMENSIONAL DRAWINGS FOR 24 TERMINAL LAYOUT FOR 24 ...
Страница 43: ...Page 43 MARIS ECDIS900 Installation Manual WIRING DETAILS FOR MK15 HATTELAND FLAT PANEL COMPUTERMK15 ...
Страница 44: ...Page 44 MARIS ECDIS900 Installation Manual HATTELAND MONITORHD26T21 ECDIS900 PCMK5 ...
Страница 63: ......
Страница 64: ... 988 10960 003 www navico commercial com ...