Simrad IS15 Скачать руководство пользователя страница 1

IS15 Instruments

Wind Manual

A L W A Y S   A T   T H E   F O R E F R O N T   O F   T E C H N O L O G Y

M

A

N

U

A

L

Содержание IS15

Страница 1: ...IS15 Instruments Wind Manual A L W A Y S A T T H E F O R E F R O N T O F T E C H N O L O G Y M A N U A L...

Страница 2: ...nual to get a thorough understanding of the operation and system components and their relationship to a complete IS15 instrument system Other documentation material that is provided with your system i...

Страница 3: ...NMEA connections added Minor corrections in text Addendum implemented Rev C New addendum on this page Rev D Addendum from rev C implemented Roblink Power Cable and IS15 Power Supply included Chapter 5...

Страница 4: ...IS15 TACK 15 4 2 Instrument Software Information 17 5 INSTALLATION 19 5 1 General 19 5 2 Instrument Head Mounting 19 5 3 Wind Transducer 21 5 4 Cabling 22 5 5 Instrument head connections 26 5 6 Wind...

Страница 5: ...IS15 Wind Manual 4 20220752G This page is intentionally left blank...

Страница 6: ...pecial power cable 2 5 m 8 Note This cable is only required when using a single IS15 Wind instrument as stand alone see Figure 1 1 The units must be interconnected as per below Wind Transducer IS15 Wi...

Страница 7: ...terface to peripheral equipment IS15 Cable Adapter joiner P N 22092001 Interconnects IS15 cables where cable extension is required Roblink Power Cable 2 5 m 8 P N 22093587 Required when using 2 or 3 i...

Страница 8: ...er indicates apparent or true wind angle depending on the mode selected The LCD Display During normal operation the LCD shows one of the items below Apparent Wind Speed True Wind Speed Velocity Made G...

Страница 9: ...st illumination and damping levels Figure 2 1 The Buttons 2 2 Powering Up When the instrument is powered up for the first time see section 6 1 First Time Turn on At normal power up the pointer will ma...

Страница 10: ...that is shown at power up The right LCD arrow is lit showing APP for Apparent The wind speed is shown in one of the selected units Knots Metres Per Second Beaufort or Kmh All units except Beaufort ar...

Страница 11: ...here is compensation for the tide and the wind direction given is the effective wind direction over the ground However the display will not be accurate after a course change and will require a period...

Страница 12: ...own 3 Press the button hold for 2 seconds and release The figure flashes 4 Select On or Off by pressing or 5 Press the button and hold for 2 seconds to save the setting 6 Press the button shortly to e...

Страница 13: ...ly if an IS15 Expander is part of the system To cancel a sounding alarm press any button on any of the instrument heads Note The flashing warning will remain as long as the alarm condition exists and...

Страница 14: ...Operation 20220752G 13 Apparent Wind Angle True Wind Angle Apparent Wind Speed True Wind Speed Boat Speed Wind Direction N Figure 2 2 Apparent True Wind and Wind Direction...

Страница 15: ...s the magnified wind angle scale which makes it useful when sailing close hauled or running down wind The operation of IS15 Tack is identical to that of IS15 Wind with the same screen menus on the LCD...

Страница 16: ...Speed Alarm Value 1 to 99 Knots Wind Speed Alarm Unit Knots Metres per Second Kmh Beaufort Wind Speed Alarm Resolution 1 Knot 1Kmh 1 m s Velocity Made Good VMG Functions VMG Display 0 to 99 9 Knots V...

Страница 17: ...ams Environmental Protection IP56 from front IP44 from rear Temperature Range Operation 0 C to 55 C 32 to 130 F Storage 30 C to 80 C 22 to 176 F 110 mm 4 33 21 mm 0 83 30 mm 1 18 85 mm Dia 3 35 Panel...

Страница 18: ...damping Improved damping of heading displays Depth transducer remains OFF at turn on if it was set to OFF while the system was running Test screens added to Installation Menu to simplify trouble shoot...

Страница 19: ...IS15 Wind Manual 18 20220752G This page is intentionally left blank...

Страница 20: ...y waterproof from the front and can therefore be installed on deck or below Caution The presence of moisture at the rear may cause damage by entering the instrument through the breathing hole The posi...

Страница 21: ...5 Open out the pilot hole to 85 mm 3 4 using a cutter in a hand held brace or an electric drill saw 86 mm or 3 3 8 6 Drill the four screw holes using a 2 5 mm 0 1 drill 7 Secure the instrument using t...

Страница 22: ...e of the transducer body in a similar way Once fitted they are held in place by a grub screw which should be tightened enough to hold the cups in place without restricting their movement Push the cups...

Страница 23: ...s Note The masthead bracket includes an integral weatherproof cap that should always be fitted to the socket if the wand has been removed 5 4 Cabling Stand Alone system W 1 Wind Transducer IS15 Wind S...

Страница 24: ...format and heading on NMEA format Integrated systems Speed temp transducer Depth transducer Supply 10 8 15 6VDC SIMRAD IS15 Combi Multi 10 m 33 10 m 33 10 m 33 IS15 Transceiver SIMRAD 0 3 m 1 IS15 Com...

Страница 25: ...1 0 3m 1 5 10m 16 33 IS15 Multi Depth IS15 Wind IS15 Compass IS15 Multi Speed IS15 Multi Depth IS15 Compass Group no 1 Group no 2 The order of instrument interconnection may be any preferred order Not...

Страница 26: ...nd Transducer Refer to section 6 6 in IS15 General Manual Securing the Cables After the ideal cable routing has been established use tie wraps P clips or other fixings to secure the cables along the r...

Страница 27: ...tions Figure 5 7 Instrument Connections The instrument head has four identical two pin connector sockets protected by rubber plugs Each socket is identified by number and signal markings Note The NMEA...

Страница 28: ...automatically configured for input listening or output talking Thus you will need a minimum of any two instrument heads to make the system both listen and talk I O Roblink cables can be ordered separa...

Страница 29: ...Junction Unit Main Board Terminal RX1 and RX1 Observe the color code for correct polarity NMEA In This will provide the instrument with heading data Connect the Roblink cable to the NMEA socket on on...

Страница 30: ...he instrument system Figure 5 11 Simrad XX32 XX40 XX50 series connection Note Even if the NMEA input is automatically polarized on the IS15 instruments it may be necessary to interchange the wires fro...

Страница 31: ...o the screw terminal as shown The connection is non polarized colour independent Red Black Screen Green White Colour independent To IS15 Transceiver Roblink socket Junction Box From Wind Transducer MH...

Страница 32: ...ent system the instruments are assigned to the system and given an Id number in the same sequence as the buttons are pressed The instrument that is assigned as 1 will be the master unit and broadcast...

Страница 33: ...ind angle Roblink On Off robl Screen Display Screen 9 Screen 10 Screen 11 Analog Digital Apparent wind angle Roblink test tESt Apparent wind angle Communication reset C rES Apparent wind angle Master...

Страница 34: ...lighting on all instruments Then the illumination bank setting must be 0 To select the illumination bank that the particular instrument shall be allocated to use the above procedure Screen 2 WIND SPEE...

Страница 35: ...ctly into the wind and then activate the automatic calibration function Any error in the wind angle will be corrected to zero the reading on the scale To activate the Wind Angle Offset Auto Calibratio...

Страница 36: ...allows you to manually change the NMEA talker port NMEA OUT to a listener port NMEA IN Hence you need not make a Master reset or a Communication reset Refer to chapter 6 1 First time turn on See also...

Страница 37: ...rved on one or more instruments This reset will not default the calibration or settings Press the button and hold for 2 seconds The LCD display shows P OFF Turn the system off refer to the beginning o...

Страница 38: ...x fastening screws Measure the voltage 10 8 15 6V Check the Roblink power cable from the Transceiver to the instruments Measure the voltage Should be 18VDC Contact your dealer One instrument in the mi...

Страница 39: ...own The anemometer cups is seized Check the anemometer cups and have the wind transducer serviced if necessary A broken anemometer cup may be replaced by the dealer customer The Wind Speed is too low...

Страница 40: ...splay monitors the data flow on the Roblink On the IS15 Wind and Tack the Roblink test monitors the data utilized by the instrument head e g wind data and compass heading Press and hold the button for...

Страница 41: ...of each season It is also recommended that the wand is removed over Winter if the boat is not in use To prevent corrosion of the connector always fit the protective cap to the socket when the wand has...

Страница 42: ...ible for any equipment lost in transit Please quote the instrument s serial number in all correspondence This may be found on the rear of the instrument 8 5 Local Master Reset When an instrument is le...

Страница 43: ...84529 Cabinet corners 44165181 Screw 3 5x32 44160232 Screw for securing the connectors 22091854 IS15 Protection cover 22092241 IS15 Panel gasket 22092753 IS15 Wind Transducer 22093017 IS15 Wind Transd...

Страница 44: ...iaouli Str EL 185 35 Piraeus Tel 30 1 413 7269 Fax 30 1 413 7270 ICELAND Fridrik A Jonsson HF Eyjarslod 7 P O Box 362 121 Reykjavik Tel 354 552 2111 Fax 354 552 2115 ITALY Simrad Srl Viale Odone Bellu...

Страница 45: ...ronics Co 7th fl Dong A Ilbo Bldg 53 11 4 KA Choongang Dong Choong Ku Pusan Tel 82 51 462 3930 Fax 82 51 462 3089 JAPAN Nippon Kaiyo Co Ltd 9 2 Sakae Cho Kita Ku Tokyo 114 0005 Tel 81 3 3913 2337 Fax...

Страница 46: ...A L W A Y S A T T H E F O R E F R O N T O F T E C H N O L O G Y www simrad com Manufacturer Simrad Egersund AS P O Box 55 N 4379 Egersund Norway Telephone 47 51 46 20 00 Telefax 47 51 46 20 01...

Отзывы: