330254/B
41
Do not connect the cable screen to the vessel's ground.
A
Junction box isolated from vessel’s
ground
B
Cable gland
C
Terminal block
D
Cable
E
Cable screen
Procedure
1
Mount the junction box in a suitable
location.
2
Terminate the steel conduits containing
the transducer cables as close to the
junction box as possible.
3
Verify that the junction box chassis is not
connected to the vessel ground.
4
If required, use necessary insulation.
5
Remove the insulation on each transducer cable, and connect the individual conductors
to the terminal block.
6
Remove the insulation on each extension cable, and connect the individual conductors
to the terminal block.
7
Verify that you have connected the wires 1:1, and that the colours match.
8
Connect the cable screens to the cable glands in the junction box.
Related topics
Installing the transducer, page 21
ES120-7C Connecting to a 12-pin Amphenol socket, page 46
12-pin Amphenol plug , page 49