Installation manual

17

851-165216 / Rev.A

Handling and maintenance

Do not lift the transducer by the cable.

Some transducers are delivered with a cover plate on the face
for protection during transport. Let this plate stay on as long as
possible, but do not forget to remove it before the vessel goes
into the sea.

An anti-fouling paint may be applied to the transducer face.
Because some paint types may be aggressive to the polyurethane
in the transducer face, please consult Simrad’s list of approved
paints on the next page.

Note

Arctic tanks have acoustic windows made of polycarbonate.
These must neither be painted nor cleaned with chemicals.

During dry docking of the vessel, the transducer face may be
cleaned for shells and other marine fouling. Be careful not to
make cuts in the transducer face. Use a piece of wood or a very
fine grade emery paper.

Содержание 50-200 COMBI C - REV D

Страница 1: ...50 200 Combi D Echo sounder transducer Installation manual M A X I M I Z I N G Y O U R P E R F O R M A N C E A T S E A www simrad com...

Страница 2: ......

Страница 3: ...851 165216 Rev A Simrad 50 200 Combi D Transducer Installation manual...

Страница 4: ...in connection with the furnishing performance or use of this document The equipment to which this manual applies must only be used for the purpose for which it was designed Improper use or maintenance...

Страница 5: ...el Also when applicable the installation shipyard must have the drawings and installation approved by the proper authorities Transducer order no KSV 203005 A cable gland kit for steel hulls is include...

Страница 6: ...en applicable Cable glands Steel conduit for transducer cable Handling and maintenance Approved anti fouling paints The information in this chapter must be regarded as general guidelines and recommend...

Страница 7: ...of high power transducers Cavitation is the formation of small bubbles in the water due to the resulting local pressure becoming negative during parts of the acoustic pressure cycles The cavitation th...

Страница 8: ...goes from laminar to turbulent The figure below illustrates the boundary layer of a vessel moving through the water Boundary water layers A Turbulent flow B Laminar flow C Air bubbles in the water Fur...

Страница 9: ...blades move upwards because the propeller cavitation is strongest on the other side The cavitation starts most easily when the water flows in the same direction as the propeller blade and that is to...

Страница 10: ...s in the fore part of the hull with maximum distance from the bow equal to one third of the total length of the hull at the water line General recommendation for transducer location A Transducer B Ang...

Страница 11: ...n steel hulls and on wood or polyester hulls respectively Inclination of the transducer face Incline the transducer face approximately 1 2 degrees D so that the flowing water meets it directly This as...

Страница 12: ...e fairing can be made of wood or steel and should have the same outline dimensions as the transducer Remember to create an air outlet E on the fairing and to fill the bolt holes with a filling compoun...

Страница 13: ...steel and should have the same outline dimensions as the transducer Use tarred felt H between th fairing and the hull Remember to create an air outlet E on the fairing and to fill the bolt holes with...

Страница 14: ...e or stainless steel bolts I and a cable bushing Note that the cable bushing must be mounted with proper gaskets 4 under and over the hull as well as sealing compound J around the its body Also fill t...

Страница 15: ...nal angle On deplacement hulls the transducer A must be mounted in an angle of 5 to 8 degrees B in relation to the keel C With a planing hull this angle must be 0 degrees A Transducer B 5 to 8 on depl...

Страница 16: ...installed in this manner are also easier to replace Some vessels may experience difficulties finding suitable areas of the hull for mounting transducer cable glands due to existing water tanks concre...

Страница 17: ...Make sure that you do not damage the transducer cable by tightening the packing nipple too hard F Cable to the echo sounder or a junction box The gland gland kit includes all of the necessary parts n...

Страница 18: ...C Rubber gaskets D Hole diameter 28 mm E Steel conduit F Cable to the echo sounder or a junction box The gland gland kit includes all of the necessary parts needed to install the unit excluding screws...

Страница 19: ...tube hole diameter 36 mm 1 5 mm Apply ample amount of sealant between the backing washer H and the hull plate The cable gland kit contains all the listed parts except the sealant Note The two O rings...

Страница 20: ...erformance The steel conduit must be unbroken and watertight from the transducer to above the water line From there the cable can be pulled further or a junction box can be installed to facilitate fur...

Страница 21: ...g paint may be applied to the transducer face Because some paint types may be aggressive to the polyurethane in the transducer face please consult Simrad s list of approved paints on the next page Not...

Страница 22: ...eamate HB 66 Antifouling Seamate HB 99 Racing Non stop From International Paints Intersleek tie coat 425 FCS BXA386 BXA390 BXA391 Grey HKA563 HKA570 HKA571 Yellow Mix BXA386 BXA390 and BXA391 first th...

Страница 23: ...drawings are for information and guidance only They are not in scale All dimensions are in mm unless otherwise is noted The drawings are available on AutoCad and or PDF format Contact your local Simr...

Страница 24: ...Simrad 50 200 Combi D Transducer 20 851 165216 Rev A 50 200 Combi D Outline dimensions...

Страница 25: ...Installation manual 21 851 165216 Rev A 50 200 Combi D Installation Connections...

Страница 26: ...Simrad 50 200 Combi D Transducer 22 851 165216 Rev A 50 200 Combi D Installation Cable gland...

Страница 27: ...Installation manual 23 851 165216 Rev A 50 200 Combi D Installation Steel fairing and mounting...

Страница 28: ...Simrad 50 200 Combi D Transducer 24 851 165216 Rev A 50 200 Combi D Installation Recommended physical location...

Страница 29: ...Notes...

Страница 30: ......

Страница 31: ......

Страница 32: ...E 2005 Simrad AS ISBN 82 8066 058 5...

Отзывы: