Simrad 38/200 Combi W
mounting ring will secure the transducer between them. Note
that several transducers use direction guides to allow correct
mounting.
Smooth surface is important
Mounting screws or bolts must not be extruding from the
transducer or the area immediately around it. Make sure that the
surface of the transducer face, the installation hardware used to
mount it, the hull plating and the putty around the transducer is
as even and smooth as possible. Obstructions on these surfaces
will create problems with turbulent flow.
Water filled
As for a blister, the interior of the tank must be filled with water.
This can be accomplished by air release through a steel tube,
which is extended either to open air 1.5 m above the water line
or to the water outside the hull at a point higher than the tank
interior.
If the tube is extended to open air, drainage must be provided
with leakage at the transducer flange or a separate hole in the
tank bottom.
Example: Flush mounting in a steel tank
Transducer mounting in a steel tank is shown in the figure below.
Figure 7
Flush mounting in a steel tank
A
Steel tank
B
Water
C
Drainage hole
D
Cable service
loop
E
Steel tube for
air outlet
F
Stuffing tube
G
Cable in steel
conduit
(CD17012A)
B
A
G
C
D
E
F
16
164986/D
Содержание 38-200 COMBI C - REV D
Страница 2: ......
Страница 42: ...Simrad 38 200 Combi W Clamping ring 204677 40 164986 D...
Страница 43: ...Drawing file 164986 D 41...
Страница 44: ...Simrad 38 200 Combi W Recommended arrangement 204678 42 164986 D...
Страница 45: ...Drawing file 164986 D 43...