background image

Input/Output Module 

Model UMI 

Simply Automated, Incorporated 

6108 Avenida Encinas, Suite B, Carlsbad, CA  92011 USA 

Technical Support:  

www.simply-automated.com

 

or 

800-630-9234

 

452-0003-0001 Rev. F     November 30, 2011 

FUNCTION 

The Input/Output Module, model UMI, is used to control UPB devices via 
scene-links triggered by low-voltage and 120VAC inputs (e.g. a contact 
closure, voltage, current, motion sensor, doorbell, telephone ring, etc.), 
and to activate low-voltage outputs based on UPB scene-links or 
commands.  The module accepts up to 3 inputs and provides 2 outputs. 
 

CAUTION:

 Do not connect voltages higher than 30Vrms/DC 

to the input/output terminals, other than telephone / 120VAC 
input #1, to prevent a shock hazard. 

INSTALLATION 

The Input/Output Module is designed for indoor use with low-voltage 
sensors and actuators, as well as a 120VAC input.  To install the UMI 
module: 

1. 

Locate a wall outlet near the wiring to be connected. 

2. 

Connect wires from the device(s) to be monitored or controlled to the 
terminal block located on the 

bottom

 of the module.  See reverse 

side for examples of applications and proper wiring diagrams.  To 
make connections, use a small tool (ball-point pen) to depress the 
orange release lever above the wire hole until the wire can be 
inserted or removed.  

3. 

Plug the UMI module into the wall outlet (see illustration below).  

4. 

If desired, another device can be plugged into the socket on the 

front

 of the module, which is always powered. 

 

 

IMPORTANT SAFETY INSTRUCTIONS 

When using electrical products, basic safety precautions should always 
be followed, including the following: 

1. 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 

2. 

Keep away from water.  If product comes into contact with water or 
other liquid, unplug immediately. 

3. 

Never use products that have been dropped or damaged. 

4. 

Do not use this product outdoors. 

5. 

Do not use this product for other than its intended use. 

6. 

Do not connect multiple devices that, when combined, exceed the 
maximum load ratings of the product. 

7. 

To avoid risk of fire, burns, personal injury and electric shock, install 
this product out of reach of small children.  

8. 

Do not cover the product with any material when in use. 

9. 

This product uses polarized plugs and sockets (one blade is wider 
than the other) to reduce the risk of electric shock.  These plugs and 
sockets fit only one way.  If they do not fit, consult a technician.   
Do not use with an extension cord unless plugs can be fully inserted.  
Do not alter plugs. 

10.  SAVE THESE INSTRUCTIONS. 

CONFIGURATION 

1. 

The UMI-32SP is preconfigured for use with the SimplySmart

TM

 

Series of Pre-Configured Kits and Accessories.  Reconfiguration of 
the UMI-32SP or UMI-32 requires UPB setup/configuration software, 
called 

UPStart

 and a model 

UMC

 Computer Interface Module.   

2. 

When configuring a UPB system, it may be necessary to place the 
UMI in SETUP mode.  To do this, press the Program Switch (see 
illustration) five times rapidly using a non-metallic tool (e.g. plastic ink 
pen or toothpick).  The indicator will continuously blink GREEN when 
the unit is in SETUP mode.  To exit SETUP mode, press the 
Program Switch once or wait five minutes. 

CAUTION:

  Do not insert metal objects into the module, 

especially in to the program switch, while it is connected 
to power. 

3. 

To configure the UMI use UPStart and assign scene-links to control 
other UPB devices. 

OPERATION 

Inputs applied to the UMI module can be set to activate or deactivate 
other UPB devices or scenes based on either the presence or absence of 
the input, or both.  UPStart, UPB configuration software, allows the user 
to select an input to operate as normally open (N.O.), or normally closed 
(N.C.) or customize the application.  Open refers to the absence of input 
signal or an open contact closure.  Closed refers to the presence of input 
signal above the threshold or a contact closure.  When the input is 
applied, the corresponding INPUT indicator will glow GREEN. 
 
Outputs operate according to commands sent by a controller or UPB 
scene-link.  When the output is ON, the corresponding OUTPUT indicator 
will glow GREEN.  The output relay can be configured to close, open or 
provide momentary closure upon receiving a UPB scene-link.  Note that 
outputs can only be activated via UPB commands, and 

not

 via inputs 

within the same module. 

UPB FACTORY DEFAULT SETTINGS 

To restore the following UMI-32-W default settings (and overwrite pre-
configured settings of UMI-32-SP), place the UMI in SETUP mode and 
then press the Program Switch ten times.  The indicator will flash RED.  
Press the switch twice to exit this mode. 
 

 

 

     

UMI-32-W  

UMI-32SP 

 

Network Name

      “Network 1” 

 

“New Network” 

 

Room Name 

     

“New Room Name” 

“New Room Name” 

Device Name       

“New CM01” 

 

“New UMI” 

Unit ID

 

     40 

 

 

13 

Network ID

 

     255 

 

 

250 

Net.  Password

      1234   

 

FFFF 

 
Input/Output 
LED Indicators

 