background image

 1

(The chances are you’re never going to read me)

Owner’s Manual

Central Vacuum Power Units

All Models

Содержание Central Vacuum Power Units

Страница 1: ... 1 The chances are you re never going to read me Owner s Manual Central Vacuum Power Units All Models ...

Страница 2: ...and Don ts 7 Operating Instructions Muffler Installation 10 Hose Hook up Inlets 11 Using the Front Utility Valve 12 Maintenance Maintenance Suggestions 13 Motor 14 Changing the HiFlow HEPA Bag 15 Dirt Receptacle 16 Filters 16 Problem Solving Guide Circuit Breaker Trips 18 Troubleshooting 19 Warranty 20 Contents ...

Страница 3: ...ts Do not pick up anything that is burning or smoking such as cigarettes matches or hot ashes Do not use without dust bag and or filters in place Turn off all controls before unplugging Use extra care when cleaning on stairs Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present Connect to a properly grounded outlet only See Grounding Inst...

Страница 4: ...ed 40 cm 16 min 30 cm 12 min 30 cm 12 7 min 30 cm 12 If the muffler is turned down 5 4 3 6 7 2 1 With muffler turned up 183 cm 72 With muffler turned down 163 cm 64 min 30 cm 12 min 30 cm 12 Recommended 40 cm 16 min 30 cm 12 min 30 cm 12 8 min 30 cm 12 If the muffler is turned down 95 cm 38 5 4 2 1 3 6 With muffler turned up 183 cm 72 With muffler turned down 163 cm 64 95 cm 38 min 30 cm 12 min 30...

Страница 5: ...ons pertaining to the preparation of PVc pipes To simplify matters installation kits including necessary fittings pipes glue and wiring as well as a detailed instruction booklet are available from Simplicity Retailers Contrary to all other connections in the piping system do not glue the last fitting to your unit Simplicity central vacuums are equipped with an adjustable air intake valve figure 3 ...

Страница 6: ...alling your vacuum inlets we recommend that the principle of electric polarity be taken into account Ensure that the wire connected onto contact A on inlet 1 is the same as that connected to contact A on inlet 2 and so on Do not cross reverse or interchange wires Do s and Don ts cont Installing Conduits ...

Страница 7: ... the low voltage wires are connected to the unit see pages 8 to 13 Then read the complete owner s manual and proceed with a quick verification of your unit s installation Check filter and bag to be sure they are properly installed Check rubber seals in each vacuum inlet Plug the hose alternatively into each vacuum inlet to ensure that each one works properly While the hose is still plugged into on...

Страница 8: ...suggestions and do not indicate a problem with your unit Your central vacuum will work normally despite the flashing LEDs When you initially connect your unit the LEDs will be green and steady HEPA Bagged Models B2 BF4 BF6 and BF10 Blinking Green Change the bag Empty the dust receptacle and clean the permanent filter Blinking Amber Plan to have your unit checked by an authorized service center soo...

Страница 9: ... Bag B2 BF4 BF6 and BF10 Models Change the bag when the one in place is two thirds full Frequency will depend on the use of the unit The maintenance suggestion module will indicate when to change the bag These indications are provided by an electronic timing board only as a reference guide see page 13 1 To access the bag unlatch the two clips and remove the dust receptacle 2 Remove the used bag an...

Страница 10: ...h the filter or replace the filter Before re installing the filter inspect it for tears or punctures If damaged or worn replace with a new filter Do not re install a damaged filter or one that is still wet or damp Carefully install the filter in the support groove to ensure adequate protection of the motor s B Note When washing the filter wash in cold water no bleach and dry at a low temperature I...

Страница 11: ...hooting Guide Problem Possible Reasons Possible Solution Vacuum system Unit not firmly plugged in Plug unit in firmly won t turn on Blown fuse or tripped breaker Check house fuse or breaker Replace fuse reset breaker Wire not connected properly Check that all wire connections are inserted in the proper locations without cross over Faulty vacuum inlet Start the vacuum unit from other inlets in your...

Страница 12: ...terations accident misuse or improper maintenance This warranty does not extend to any power nozzle accessory kit or accessories used in conjunction with this power unit Simplicity power nozzle accessory kits are covered under a separate warranty What Simplicity Will Do This warranty provides at no cost to you all labor and parts to keep this central vacuum power unit in correct operating conditio...

Страница 13: ... 22 www simplicityvac com 2008 Tacony Corporation IB SPU ...