4901 TrueAlert

®

 Non-Addressable Horn 

Installation Instructions

 

 

CAUTION:

 

When switch SW1 is in the 
SmartSync mode, the horn will not 
operate unless connected to a 
SmartSync control module (4905-
9938), 4010 fire alarm control panel, 
or 4009 IDNet NAC extender. The 
factory default setting for SW1 is 
“OFF.”  

 

Cautions and Warnings

 

 

READ AND SAVE THESE INSTRUCTIONS

- Follow the instructions in this installation manual. These 

instructions must be followed to avoid damage to this product and associated equipment. Product operation 
and reliability depend upon proper installation. 

DO NOT INSTALL ANY SIMPLEX

®

 PRODUCT THAT APPEARS DAMAGED

-

 

Upon unpacking your 

Simplex product, inspect the contents of the carton for shipping damage. If damage is apparent, immediately 
file a claim with the carrier and notify an authorized Simplex product supplier. 

ELECTRICAL HAZARD- 

Disconnect electrical field power when making any internal adjustments or repairs. 

All repairs should be performed by a representative or authorized agent of your local Simplex product 
supplier.

 

STATIC HAZARD

-

 

Static electricity can damage components. Handle as follows: 

 

Ground yourself before opening or installing components. 

 

Prior to installation, keep components wrapped in anti-static material at all times. 

 

FCC RULES AND REGULATIONS – PART 15-

 This equipment has been tested and was found to comply with the limits 

for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference when the equipment is operated in a commercial environment. This equipment 
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction 
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is 
likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 

 

SAFETY OF NOTIFICATION APPLIANCES

 

-

 

Always install, maintain, and test notification appliances within their 

specifications. 

Failure to follow all safety precautions and instructions may result in loss of life and property due to non-

functioning notification appliances.

 

Some notification appliances use high voltage. 

To avoid electrical hazards and damage to appliances, make sure that the electrical 

power for the notification appliance circuit is disconnected at the control panel. Disconnect before installing, repairing, or internally 
adjusting any notification appliances. 

Even with electrical power removed, some notification appliances store a high voltage charge. This high voltage can cause injury 
resulting in death from electrical shock. DO NOT TOUCH EXPOSED CIRCUITRY. 

 

 

The 4901-6820 and 4901-9820 TrueAlert horn (see Figure 1) is 
a non-addressable wall-mounted notification appliance that 
provides an audible indication of an alarm condition. It is 
activated from the control panel of a UL-listed, Simplex fire 
alarm system. 

When the notification appliance emits sound, 

it indicates the possibility of an emergency situation that 
requires your immediate attention.

 

 

The horn is a notification appliance that operates on a reverse 
polarity notification appliance circuit (NAC). When this NAC 
circuit is in the reverse polarity, or supervision state, the horn 
does not operate, and introduces high impedance to the circuit. 
The horn operates when the NAC changes polarity, to enter the 
“alarm” state. 

 

When the horn powers up, it checks the setting of the Switch 
(SW1) to determine whether to operate in either Free-Run 

(SW1 “OFF”)

 or SmartSync

 (SW1 “

ON”)

 Mode. If the 

switch is set for Free-Run mode, the horn sounds for as long 
as power is applied. Otherwise, the horn waits in silence for 
commands from the NAC. 

 

When set for SmartSync mode, the horn responds to Turn-
ON, Turn-OFF, March Time, and Temporal command 
signals received from the SmartSync circuit. The horn 
responds immediately on any valid command received to reset the sounder operation to the new mode. The horn will 
produce an audible, ½ second pulse every 1.0 second when either March Time or Temporal command is detected, with 
every fourth pulse removed, under the Temporal (Code 3) command. See Table 1 for information about sound output 
levels and current draw on the TrueAlert horn. 

 

TrueAlert 
Non-
Addressable 
Horn 
Operation 

 

 

Figure 1. TrueAlert Horn 

 

  

 

 

 

 

© 2005-2015 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without 
notice.  
Tyco, Simplex, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. 

574-720 

Rev. G 