6.3.3 Installation of SKG/VdS cylinders
Loosen the outside knob's threaded pin using an Allen key. Do not unscrew
completely. Hold the inside knob firmly and then turn the outside knob
anti-clockwise.
Turn the cam until it is vertical and pointing downwards. Insert the digital
locking cylinder through the lock from the inner side. Fasten the cylinder
into the mortise lock with the fastening screw. Then screw the outside knob
back into position on the cylinder and tighten the threaded pin.
6.3.3.1 Installation of core extraction protection adapters (Z4.KA.SET)
The core extraction protection adapter (Z4.KA.SET) is compatible with all
SKG/VdS cylinders manufactured up to 2010 and all .FD cylinders.
Instructions:
1. Disassemble the non-electronic knob.
2. Remove the rubber seal on the tip of the outside tube.
3. Place the core extraction protection adapter on the outside tube and
turn while applying a little pressure, so that it grips into the indents on
the flange (in a similar way to the knob when installed). The openings in
the adapter and the outside tube web must align.
4. Insert the supplied screw through the lock and tighten carefully.
5. Replace the knob and turn in an anti-clockwise direction while applying
slight pressure until the outer knob grips into the indents in the flange.
Possibly place the knob in this position by pressing it gently towards the
profile cylinder housing.
NOTE
Turning the bayonet disc when not installed may prevent the thumb-turn
from being fastened into position. In such a case, push the disc back into
the original 'bayonet disc open' position using the installation tool.
6. Place the installation key on the outside thumb-turn in such a way that
its two teeth engage into the outside thumb-turn (if necessary, turn the
thumb-turn until both teeth lock into the locking disc). Lock the thumb-
turn into position again by rotating it 30° in a clockwise direction.
6.3.3.2 Installation of core extraction protection adapters (Z4.KA.SET2)
The core extraction protection adapter (Z4.KA.SET2) is compatible with all
SKG/VdS cylinders manufactured from 2011 onwards.
Instructions:
1. Disassemble the non-electronic knob.
Digital Locking Cylinder 3061
(Manual)
6. Installation instructions
30 / 54