User manual - COUNTER SLN-94
7.3.1.
“rL1”, “rL2” menu
This menu contains options of configuration of operation of relay
R1
and
R2
. Principle of
the relay operation is described in paragraph
CONTROL OF THE RELAY OUTPUTS...
.
“Pr1”,
“Pr2”
- selection of relays thresholds (range 0 ÷ 999).
a) in standard mode („
mod
” = „
Std
”)
For upcounting relay
R1
is driven to
active
state when counter reaches
value ”
Pr1
”, and for downcounting when counter reaches ”
000
”. Relay R2
is unavailable in standard mode
b) in batcher mode („
mod
” = „
bAt
”)
While upcounting relay
R1
is driven to its
inactive
state when
counter reaches ”
Pr1
” value, and relay
R2
when counter reaches value
(”
Pr1
” - ”
Pr2
”). For downcounting relay
R1
is driven to its
inactive
state
when counter reaches value „
000
”, and relay
R2
when counter reaches
value ”
Pr2
”.
“tr1”, “tr2”
- In standard mode („
mod
” = „
Std
”) this is time while relays stay in their
active
states
,
in batcher mode („
mod
” = „
bAt
”) this is time while relays stay in their
inactive
state
.
Available range: ”0.0” ÷ ”99.9” express time in seconds.
Selection of ”0.0” causes holding relays in their states (inactive and active
respectively depending on mode) until next initialisation of the cycle.
“mr1”,
“mr2”
- method of relays operation. This parameters defines
active
state of the
relays. In standard mode („
mod
” = „
Std
”)
active
state means the state of the
relay set after counter reaches selected threshold. In batcher mode („
mod
” =
„
bAt
”)
active
state of the relay is set directly after initialisation of the cycle.
There available 4 possibilities:
“noA”
- relay is disabled, always open;
“on”
- relay is closed in active state;
“oFF”
- relay is open in active state;
“mb”
- relay is driven via serial RS 485 interface, independently of counter state
parameters “
Pr1
”,
“
Pr2
”, “
tr1
” and “
tr2
”.
•
When contacts of relay are closed, particular LED lights,
•
If “
mb
” mode is active then after power up particular relay is open, in other
modes (“
on
”and “
oFF
”) relay will be set to its
inactive
state.
7.3.2.
“rES”
parameter
This parameter determines the counter zeroing (reset) sources, and can be set to one of
the values:
”ALL”
- this option enables both manual (using
[ESC/RESET]
button) and electronic reset.
27
i