Troubleshooting 

13

For parts or assistance, call Simer Customer Service at 1-800-468-7867

Symptom

Possible Cause(s)

Corrective Action

Motor will not run

Disconnect switch is off

Be sure switch is on.

Fuse is blown or circuit breaker tripped

Replace fuse or reset circuit breaker.

Starting switch is defective

DISCONNECT POWER; Replace starting switch.

Wires at motor are loose, disconnected, or 
wired incorrectly 

Refer to instructions on wiring (Page 9). DISCONNECT POWER; check and 
tighten all wiring.

 Capacitor voltage may be hazardous. To discharge capacitor, 

hold insulated handle screwdriver BY THE HANDLE and short capacitor 
terminals together. Do not touch metal screwdriver blade or capacitor terminals. 
If in doubt, consult a qualified electrician.

Pressure switch contacts are dirty

DISCONNECT POWER and file contacts with emery board or nail file.

Motor runs hot and overload 
kicks off

Motor is wired incorrectly

Refer to instructions on wiring.

Voltage is too low

Check with power company. Install heavier wiring if wire size is too small (See 
Electrical / Wiring Chart).

Pump cycles too frequently

See section below on too frequent cycling.

Motor runs but no water is 
delivered*

Pump in new installation did not pick up 
prime through: 
1. Improper priming 
2. Air leaks
3. Leaking foot valve or check valve

In new installation:
1. Re-prime according to instructions.
2. Check all connections on suction line, AVC, and ejector with soapy water or 
shaving cream.
3. Replace foot valve or check valve.

Pump has lost prime through:
1. Air leaks
2. Water level below suction pipe inlet

In installation already in use:
1. Check all connections on suction line and shaft seal.
2. Lower suction line into water and re-prime. If receding water level in well 
exceeds 25’ (7.6M), a deep well pump is needed.

Foot valve or strainer is plugged

Clean foot valve or strainer.

Ejector or impeller is plugged

Clean ejector or impeller.

Check valve or foot valve is stuck shut 

Replace check valve or foot valve.

Pipes are frozen

Thaw pipes. Bury pipes below frost line. Heat pit or pump house.

Foot valve and/or strainer are buried in 
sand or mud

Raise foot valve and/or strainer above bottom of water source. Clean foot valve 
and strainer.

Water level is too low for shallow well 
setup to deliver water

A deep well jet will be needed if your well is more than 25’ (7.6M) depth to 
water.

Pump does not deliver water to 
full capacity (Also check point 3 
immediately above)

Water level in well is lower than estimated

A new nozzle and venturi combination may be needed.

Steel piping (if used) is corroded or limed, 
causing excess friction

Replace with plastic pipe where possible, otherwise with new steel pipe.

Piping is too small in size

Use larger piping.

Pump delivers water but does 
not shut off or pump cycles too 
frequently

Pressure switch is out of adjustment or 
contacts are welded together

DISCONNECT POWER; adjust or replace pressure switch.

Faucets have been left open

Close faucets.

Venturi, nozzle or impeller is clogged

Clean venturi, nozzle or impeller.

Standard pressure tank is waterlogged and 
has no air cushion

Drain tank to air volume control port. Check AVC for defects. Check all 
connections for air leaks.

Pipes leak

Check connections.

Foot valve leaks

Replace foot valve.

Pressure switch is out of adjustment

Adjust or replace pressure switch.

Air charge too low in pre-charged tank

DISCONNECT POWER and open faucets until all pressure is relieved. Using 
tire pressure gauge, check air pressure in tank at valve stem located on the tank. 
If less than pressure switch cut-in setting (30-50 PSI), pump air into tank from 
outside source until air pressure is 2 PSI less than cut-in setting of switch. Check 
air valve for leaks (use soapy solution) and replace core if necessary.

Air spurts from faucets

Pump is picking up prime

When pump has picked up prime, it should pump solid water with no air.

Leak in suction side of pump

Suction pipe is sucking air. Check joints for leaks with soapy water.

Well is gaseous

Consult factory about installing a sleeve in the well.

Intermittent over-pumping of well. (Water 
drawn down below foot valve.)

Lower foot valve if possible, otherwise restrict pump discharge.

* Stop pump; then check 
prime before looking for 
other causes. Unscrew 
priming plug and see if 
water is in priming hole.

Содержание 3305P

Страница 1: ...g installation or maintenance assistance Call 1 800 468 7867 English Pages 2 16 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Co...

Страница 2: ...tor terminals If in doubt consult a qualified electrician General Safety Do not touch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump a...

Страница 3: ...pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local disposal ordinances Exceptions to the Twelve 12 Month...

Страница 4: ...motor 1 Drain and remove the old pump Check the old pipe for scale lime rust etc and replace it if necessary 2 Install the control valve and pressure gauge in the pump body see Figure 1 3 Install eje...

Страница 5: ...ee well points to one suction pipe You have just completed the suction piping for your new shallow well jet pump Please go to Page 8 for discharge pipe and tank connections 1 E I DuPont de Demours and...

Страница 6: ...foot valve and suction pipe see Figure 9 Make sure that the foot valve works freely Use Teflon tape or a Teflon based pipe joint compound on threaded pipe joints Protect the foot valve assembly from...

Страница 7: ...2 Well Figure 11 1 Install the control valve and pressure gauge in the pump body See Figure 7 2 Mount the pump as close to the well as possible 3 Assemble ejector kit FP4840 kit sold separately well p...

Страница 8: ...he open arm of the first tee Put a priming plug in one arm of the second tee 3 Run a pipe from the open arm of the second tee to the inlet port of your tank The pipe size must be at least as large as...

Страница 9: ...s Use the wire size including the ground wire specified in the wiring chart If possible connect the pump to a separate branch circuit with no other appliances on it Explosion hazard Do not ground to a...

Страница 10: ...the pressure switch and the motor for motor grounding protection If the pressure switch is not connected to the motor connect the green ground screw in the switch to the green ground screw under the...

Страница 11: ...control valve each time before you start the pump 5 When water pressure has built up and is maintained by the pump slowly open the control valve see Figure 18 this will let water flow to the residenti...

Страница 12: ...wer on Start the pump The pump should pump water in two or three minutes 4 If you don t have water after 2 or 3 minutes stop the pump and remove the fill plugs Refill the pump and piping You may have...

Страница 13: ...r pump house Foot valve and or strainer are buried in sand or mud Raise foot valve and or strainer above bottom of water source Clean foot valve and strainer Water level is too low for shallow well se...

Страница 14: ...Pump Body Front Half L76 37P 7 Control Valve Assembly L162 10PS 8 Overhaul Kit FPP1511 FPP1512 FPP1513 9 Pressure Switch Assembly TC2151 Ref Part Description Model and HP 3325E 1 2HP 3327E 3 4HP 1 Mot...

Страница 15: ...Venturi Shallow Well 3327E N32P 67B 4 Gasket N20 25 5 Pipe Plug U78 56ZPS 6 Socket Head Capscrew 2 Req U30 961PS 7 Check Valve N212 12P Shallow Well Kit FP4855 for 3325E 3327E NOTICE Use care not to d...

Страница 16: ...well is more than the distance listed in the Depth column for your pump you MUST use the nozzle venturi combination listed or your pump will not be able to lift water from the well Nozzle Venturi Com...

Страница 17: ...us pour fonctionner par des temp ratures lev es Pour ne pas se br ler lorsque l on interviendra sur la pompe la laisser refroidir pendant 20 minutes apr s l avoir arr t e avant de la toucher Ne pas l...

Страница 18: ...fins de garantie retourner l tiquette figurant sur le cordon de la pompe et l original du re u au d taillant Mettre la pompe au rebut conform ment la r glementation locale Exceptions la garantie limi...

Страница 19: ...e et le manom tre dans le corps de la pompe voir la Figure 1 3 Poser le n cessaire d jecteur FP4875 ou le n cessaire FP4855 les n cessaires sont vendus s par ment Suivre les instructions fournies avec...

Страница 20: ...e jecteur neuve pour puits profonds sur la tuyauterie du puits est maintenant termin Passer la page 23 pour le branchement du tuyau de refoulement et sur un r servoir 1 E I DuPont de Demours and Compa...

Страница 21: ...a Figure 9 S assurer que le clapet de pied fonctionne librement Utiliser du ruban T flon ou de la p te pour raccords filet s base de T flon sur les raccords filet s Poser une cr pine autour du clapet...

Страница 22: ...terie du puits et l adaptateur de la t te du puits conform ment aux instructions fournies avec l jecteur Voir la Figure 11 Utiliser un tuyau de descente galvanis muni de raccords usin s pour assurer u...

Страница 23: ...me t et l orifice d admission du r servoir Le diam tre du tuyau doit tre au moins aussi grand que le diam tre de l orifice de refoulement de la pompe 4 D poser le bouchon filet de 1 8 de pouce NPT de...

Страница 24: ...er la pompe sur un circuit s par sur lequel aucun autre appareil ne sera branch Risque d explosion Ne pas mettre la terre sur une conduite de gaz Figure 15 Tension r gl e 115 V sur s lecteur cadran Fi...

Страница 25: ...n 2 Il doit y avoir un raccordement en m tal solide entre le manostat et le moteur pour une protection la terre du moteur Si le manostat n est pas branch sur le moteur brancher la vis verte de mise la...

Страница 26: ...tenue par la pompe ouvrir lentement la vanne de r gulation voir la Figure 18 pour que l eau circule dans les conduites de l habitation Observer la pression indiqu e par l aiguille du manom tre Continu...

Страница 27: ...per l eau dans les deux ou trois minutes qui suivent 4 Si la pompe ne pompe pas d eau dans les 2 ou 3 minutes qui suivent l arr ter et d poser les bouchons de remplissage Faire le plein de la pompe et...

Страница 28: ...pet de pied et ou la tr mie sont enfouis dans le sable ou la boue Relever le clapet de pied et ou la cr pine plus haut que le fond de la source d eau Nettoyer le clapet de pied et la cr pine Dans le c...

Страница 29: ...ses avec tous les n cessaires de r paration R f D signation Mod le et puissance en ch 3305P 1 2 ch 3307P 3 4 ch 3310P 1 ch 1 Moteur J218 582A 115 PKG J218 590 PKG J218 596 PKG 2 Manom tre TC2104 3 Cor...

Страница 30: ...s le sch ma ci dessus sinon il risquera d y avoir des fuites internes 1 2 3 4 5 12 6 7 8 9 10 11 1722 0495 Trousse pour puits peu profond FP4875 Pour 3305P 3307P et 3310P Ref D signation Num ro des pi...

Страница 31: ...s 1 1 4 NPT 5 U11 1 Pi ces non illustr es Gicleur Venturi Combinaison Trousse FP4800 Modele Profondeurs inf rieures Gicleur Venturi Profondeurs inf rieures Gicleur Venturi 3305P 50 15 2 m J34P 41 51...

Страница 32: ...para operar a temperaturas altas Para evitar quemaduras al realizar el servicio a una bomba d jela enfriar por 20 minutos despu s de apagarla No permita que la bomba o cualquier componente del sistem...

Страница 33: ...omba cloacal ha fallado Use guantes de caucho cuando manipule la bomba Para los fines de la garant a devuelva la etiqueta del cord n de la bomba y el recibo de compra original a la tienda minorista De...

Страница 34: ...1 3 Instale el kit de eyector FP4875 o el kit FP4855 los kits se venden por separado Siga las instrucciones que vienen incluidas en el kit Aseg rese de alinear el venturi con el orificio superior en...

Страница 35: ...scarga 1 E I DuPont de Demours and Company Corporation Delaware In stalacion de pozo recubierto con un recubrimiento de 2 o mas Figura 6 1 Instale la v lvula de control y el medidor de presi n en el c...

Страница 36: ...tuber a Proteja la conexi n de la v lvula de retenci n de peces basura etc con la instalaci n de una malla de alambre a su alrededor vea la Figura 9 5 Baje la tuber a hacia el agua hasta que el filtro...

Страница 37: ...e cabeza del pozo de acuerdo con las instrucciones que vienen incluidas en el paquete del eyector Vea la Figura 11 Utilice tubo galvanizado de ca da con juntas invertidas para lograr un flujo adecuado...

Страница 38: ...entrada de su tanque La tuber a debe ser al menos del mismo tama o que el orificio de descarga de la bomba 4 Retire el tap n de la tuber a de 1 8 de NPT del orificio del Control de Volumen de Aire CVA...

Страница 39: ...es posible conecte la bomba a un circuito separado de derivaci n sin ning n otro artefacto en el mismo Peligro de explosi n No haga la conexi n a tierra en una l nea de suministro de gas Figura 15 Te...

Страница 40: ...esi n y el motor para brindar protecci n a tierra para el motor Si el conmutador a presi n no est conectado al motor conecte el tornillo de puesta a tierra verde en el conmutador al tornillo de puesta...

Страница 41: ...la v lvula de control consulte la Figura 18 esto permitir que el agua corra a las tuber as de la residencia Abra lentamente la v lvula de control mientras observa la aguja del man metro Contin e abri...

Страница 42: ...que la bomba La bomba debe bombear agua despu s de 2 3 minutos 4 Si no tiene agua despu s de 2 3 minutos pare la bomba y retire todos los tapones de llenado Vuelva a llenar la bomba y la tuber a Posib...

Страница 43: ...iente el recinto de bombas o el foso La v lvula de pie y o el colector est n enterrados en arena o en lodo Eleve la v lvula de pie y o el colector por encima del fondo de la fuente de agua Limpie la v...

Страница 44: ...de reparaci n Ref Descripci n Modelo y HP 3305P 1 2HP 3307P 3 4HP 3310P 1 HP 1 Motor J218 582A 115 PKG J218 590 PKG J218 596 PKG 2 Medidor de Presi n TC2104 3 Cuerpo de la Bomba Mitad trasera L176 47...

Страница 45: ...22 0495 Juego para pozo poco profundo FP4875 Para bombas de la 3305P 3307P y 3310P N32P 67 4 1 1 2 3 Surface B 6 7 5 4 1927 1204 Superficie B Ref Descripci n N mero de repuesto 1 Unidad del eyector N4...

Страница 46: ...idad menor que Tobera Venturi Profundidad menor que Tobera Venturi 3305P 50 15 2 m J34P 41 51 J32P 24 70 21 3 m J34P 42 52 J32P 18 3307P 70 21 3 m J34P 43 53 J32P 24 100 30 5 m N A 3310P 90 27 4 m N A...

Страница 47: ......

Страница 48: ......

Отзывы: