Installation / Operation

6

For parts or assistance, call Simer Customer Service at 

1-800-468-7867 / 1-800-546-7867

ELECTRICAL CONNECTION

Hazardous voltage. Risk of dangerous or

fatal electric shock. Plug the pump into a 115 Volt, 60
Cycle, Ground Fault Circuit Interrupter (GFCI) protect-
ed grounded outlet only. The pump is equipped with a
3-wire grounded cord and plug.

Do not modify or

remove the plug. Make sure the outlet meets the
National Electric Code or the Canadian Electrical Code,
as applicable. To avoid dangerous electrical shock haz-
ard, keep the cord dry at all times. See Figure 2.

AUTOMATIC PRESSURE CONTROLLER

The Automatic Pressure Controller mounts on the pump.
It protects against:
• Run-dry operation;
• Overheating;
• Frequent starts caused by small water losses in the system;
• Pressure drop.
The Automatic Pressure Controller features the following
LEDs and controls:
“POWER ON” LED: indicates that the unit is electrically
connected and that voltage is present. The pump is ready
to operate.
“PUMP ON” LED: indicates that the pump is running
and actually pumping water.
“WATER FAILURE” LED: indicates that no water is
detected coming into the pump.
“TEMPERATURE FAILURE” LED: indicates that the tem-
perature inside the pump has reached 158° F (70° C). 

“Starting Pressure” dial: allows you to set the system
pressure at 15 to 45 psi (103 to 310 kPa). The pump will
start automatically when the system pressure drops
below the pressure point which you have set on the
“Starting Pressure” dial.
“Reset” button: resets any safeties which have tripped
and allows the pump to restart.

NOTE:

The unit will not respond if the ‘RESET’ button is

held down. It must be pressed and released to activate
the reset function.

NORMAL OPERATION OF THE 3075SS

Burn Hazard.

NEVER run the pump dry.

Running the pump without water may cause pump to
overheat and cause burns to persons handling the pump.
It may also damage the impeller and may damage the
seal, causing leaking or flooding, and will void the war-
ranty. Fill the pump with water before starting it.
Make sure that the 3075SS has been properly installed,
primed (see page 4), and that the suction pipe is unob-
structed and open.
Turn the ‘STARTING PRESSURE’ dial to the minimum
desired system pressure.
Plug in the pump. The ‘POWER ON’ and ‘PUMP ON’
lights will come on indicating, respectively, that voltage
is present and that the pump is ready to operate.
The pump will start and will continue to operate until 15
seconds after the system pressure has risen past the set-
point on the “STARTING PRESSURE” dial and flow has
stopped.

WHEN DOES THE PUMP 
STOP OPERATING? 

Pressure Set-Point/No Flow:

The pump will stop operat-

ing and the ‘PUMP ON’ LED will go off 15 seconds after:
• The system pressure is above the point set by the

STARTING PRESSURE dial, and 

• The flow has stopped. 

This is normal operation.

Restart: 

A water flow in the system greater than 

1 GPM or a drop in pressure below the STARTING
PRESSURE set-point  will cause the pump to restart and
the ‘PUMP ON’ LED to light up. The pump will contin-
ue to operate until 15 seconds after:
• It reaches the set pressure, and
• The flow stops.

NOTE:

The 15-second delay in shutting off the pump

prevents rapid cycling when water faucets are being
turned on and off quickly (for example, when brushing
teeth, etc.). 

W

ater Fail

u

re LED

P

u

mp-on LED

Po

w

er-on LED

Temp. Fail

u

re LED

Starting 
Press

u

re 

Dial

RES

ET

W

ATER F

AILURE

TEMP

. FAILURE

PUMP O

N

PO

W

ER O

N

STAR

TI

N

G

PRESSURE

1-

8

00-4

6

8

-7

8

67

ww

w

.sim

erp

u

mp

.co

m

20

15

25

35

30

40

45

PSI

Reset

RE

SE

T

W

AT

ER

 FA

ILU

RE

TE

MP

. F

AIL

UR

E

PU

MP

 O

N

PO

W

ER

 O

N

STA

RT

I

N

G

PR

ES

SU

RE

1-

8

00-365-6

8

32

www

.flotec

w

ater

.com

20

15

25

35

30

40

45

PS

I

3963 0401 SIM

®

®

Figure 5 - Control Panel

Содержание 3075SS

Страница 1: ...n Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 468 7867 Fran ais Pages 10 16 Instalaci n Operaci n Piezas Para mayor infor...

Страница 2: ...er nal parts overheat pump which can cause burns to people handling or servicing pump and will void warranty 6 Risk of fire or explosion To avoid risk of fire and explosion Pump Water Only with this p...

Страница 3: ...ion tampering alteration nor due to improper installation operation maintenance or storage nor to other than normal application use or service including but not limited to operational failures caused...

Страница 4: ...ossible number of fittings Long pipe runs and numerous fittings increase friction and reduce the flow of water Support the weight of the piping and pump Do not allow the pump pressure controller or an...

Страница 5: ...e in the pump suction line The arrow on the check valve must point to the pump suction see Figure 2 If not already in the plumbing sys tem install a pressure relief valve in the pump discharge line ca...

Страница 6: ...the pump without water may cause pump to overheat and cause burns to persons handling the pump It may also damage the impeller and may damage the seal causing leaking or flooding and will void the war...

Страница 7: ...dur ing operation if the water supply to the pump fails To protect the pump from running dry 15 seconds after it detects no water the pump will stop operating The PUMP ON LED will go out and The WATE...

Страница 8: ...1 2 6 5 4220 0702 4 3 Key Part No 3075SS No Description Used 1 2 HP 1 Pump Body Kit includes Bolts 1 FPP1801 2 Internal Parts Kit 1 FPP1870 3 Capacitor 1 171P5750 4 Wiring Box Cover Gasket Kit 1 FPP18...

Страница 9: ...9 For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867...

Страница 10: ...its chimiques Ne pas utilis er cette pompe pr s de veilleuses fonctionnant au gaz ni en pr sence de vapeurs de produits chimiques d essence ou de tout autre produit inflammable L utilisation d une lec...

Страница 11: ...s ou entretenus correctement ni ceux qui n ont pas t utilis s ou entretenus normalement y compris mais sans s y limiter aux produits ayant des pannes de fonctionnement caus es par la corrosion la roui...

Страница 12: ...ble et le moins possible de raccords De grandes longueurs de tuyau et de nombreux raccords augmentent le frottement ce qui diminue le d bit de la pompe Supporter le poids de la tuyauterie et de la pom...

Страница 13: ...p e sur le clapet de non retour doit tre orient e vers l aspiration de la pompe se reporter la Figure 2 Sur la conduite de refoulement poser une soupape de s ret qui permettra d vacuer tout le d bit d...

Страница 14: ...seur et le joint de l arbre de la pompe peuvent galement tre endommag s si la pompe fonctionne sec ce qui pourrait causer des fuites ou une inondation De plus la garantie sera annul e Avant de d marre...

Страница 15: ...pompe et le servor gulateur d brancher le cordon lectrique de la prise de courant Ne pas manipuler la pompe ni le servor gulateur et ne pas essayer d intervenir sur la pompe si on a les mains humides...

Страница 16: ...702 4 3 D signation 3075SS R f des pi ces Qt 1 2 ch 1 Corps de la pompe comprend les boulons 1 FPP1801 2 Trousse des pi ces internes 1 FPP1870 3 Condensateur 1 171P5750 4 Trousse de bo te de c blage C...

Страница 17: ...17 Pour obtenir des pi ces ou de l aide appeler le Service la client le Simer en composant le 1 800 468 7867 1 800 546 7867...

Страница 18: ...ua sola mente con esta bomba No bombee l quidos ni sustancias qu micas inflamables No use la bomba cerca de luces piloto de gas o en reas en presencia de vapores qu micos o de gases El uso de una bomb...

Страница 19: ...o indebido alte raciones ni debido a instalaci n funcionamiento mantenimiento o almacenaje incorrectos ni a ninguna otra cosa que no sea su aplicaci n uso o servicio normales incluyendo pero no limita...

Страница 20: ...ctos de tuber a largos y numerosos accesorios aumentan la fricci n y reducen el flujo del agua Apoye el peso de la tuber a y de la bomba No permita que la bomba el controlador de presi n ni ning n com...

Страница 21: ...nes del c digo 9 Instale la tuber a desde los codos a la bomba incluyendo una uni n en cada l nea y una v lvula checadora en la l nea de aspiraci n de la bomba La flecha en la v lvula checadora debe a...

Страница 22: ...podr recalentar y podr quemar a las personas que est n manipulando la bomba Tambi n podr da ar el impulsor y el sello provocando fugas o inundaci n y anular la garant a Llene la bomba con agua antes...

Страница 23: ...eparaci n o mantenimiento en los mismos No maneje la bomba ni el controlador ni trate de tra bajar en la bomba con manos mojadas o cuando est parado sobre un piso mojado o h medo El motor tiene un pro...

Страница 24: ...Descripci n 3075SS No de la pieza Cantidad 1 2 HP 1 Juego de unidad de bomba incluye pernos 1 FPP1801 2 Juego de repuestos internos 1 FPP1870 3 Capacitor 1 171P5750 4 Juego de caja de cables Cubierta...