6.8 Datalogging (de-)activation.

If required, the Manager can log data regarding the operation of the bar.
To (de)activate this data logging, the parameter 

Datalogging 

has to be changed.

For detailed information on data logging, please refer to the manual Manager IQ Easy

- [

(n)x

Data logging

select

On

or

Off

]

6.9 Clean bar warning level setup (expert mode)

The IQ Easy Ex bar should after calibration (6.3) continuously monitor the effectiveness of the 
bar. Should the effectiveness fall below the set 

Clean bar warning 

level due to contamination,

buildup or other causes, a warning (LED on the bar blinking red / green and a orange icon will 
be generated on the Manager).
By default, this level is set to 50 %, but it can be set to a different value in specific cases

- [

(n)x

Clean bar warning level

with the slider or with 

select the 

required value and confirm with 

]

7 Checking the Functionality

7.1 Checking neutralization

To measure the efficiency of the anti-static bar, a field strength meter can be used, which is 
suitable for use in hazardous areas.
Connect the field strength meter with the grounding, keep a minimum distance of 30 cm from 
the anti-static bar.
Measure the static charge of the material before and after it has passed the anti-static bar.
The measured charge must have minimized after the material has passed the anti-static bar.

7.2 Checking functionalities via the LED’s

The color of the status-LED’s of the anti-static bar and Ex Status Module show the status of the
anti-static bar. The Ex-Status Module shows only that the fuse is functioning and that voltage is 
supplied to the bar = green Blinking, regardless if the bar is in use or on standby.

Table 1, overview status indicators anti-static bar & Ex Status Module

Display Manager 

indication

LED-indicator

Performax IQ Easy Ex

Led-indicator 

Ex Status Module

Status

High Voltage 

output

green

Green Blinking 1 Hz

Green Blinking 1 Hz

Stand-by

Off

blue

Green

Green Blinking 1 Hz

In operation

On

orange

Red / Green Blinking

1Hz

Green Blinking 1 Hz

Clean Bar

On

red

Red

Green Blinking 1 Hz

High voltage overload

On

grey

Red Blinking 5Hz

Green Blinking 1 Hz

No communication

On/Off*

grey

Off

Red

Fuse on Ex Status 

Module defective

Off

* When bar is in RUN mode it will continue to function in Fixed Mode / when in Stand-by it will stay in stand-by

Содержание ION Performax IQ Easy Ex

Страница 1: ...e antistatique 1180 II 2 GD Ex mb IIB T4 Gb Ex mb IIIB T135 C Db SIMCO Nederland B V Postbus 71 NL 7240 AB Lochem Telefoon 31 0 573 288333 Telefax 31 0 573 257319 E mail general simco ion nl Internet http www simco ion nl Traderegister Apeldoorn No 08046136 NL Gebruikershandleiding D Bedienungsanleitung GB User Manual 1 32 66 FR Mode d emploi 98 ...

Страница 2: ...PERT mode for setting parameters or maintenance tasks 82 6 3 Calibrating the Performax IQ Easy Ex through the IQ Easy Platform 82 6 4 Operating modes expert 83 6 4 1 Operation Mode Manual 84 6 4 2 Operation mode CLFB Closed Loop FeedBack with IQ Easy sensor 85 6 5 Anti static bar Standby Active and Autorun setting 85 6 6 Anti static bar Information parameters expert mode 86 6 7 Switching the bar o...

Страница 3: ...our entitlement under the guarantee The terms of the guarantee are set out in the Simco Ion Netherlands General Terms and Conditions of Sale Explanation of symbols Warning Indicates special information to prevent injury or significant damage to the product or the environment Attention Important information for making the most efficient use of the product and or for preventing damage to the product...

Страница 4: ... conductors to the IQ Easy platform With the IQ platform the anti static bar can be controlled and read out centrally and remotely Using the IQ Easy platform the status of the bar can be logged making quality management easier The Performax IQ Easy Ex is optimally deployed between 100 and 300 mm away from the material at material speeds below 500 meters per minute and is available in effective len...

Страница 5: ...ns from the anti static bar are exchanged with the charged material until the material is neutralized You can see via the status LED if the anti static bar is in operation and if it is overloaded In addition through the Manager IQ Easy divers parameters limit values and information concerning the functioning efficiency can be recorded and logged To learn more refer also to the user manual of the M...

Страница 6: ...eed in such a way there is no possible mechanical damage The Performax IQ Easy Ex should be mounted at a distance of 100 to 300 mm The Performax IQ Easy Ex Speed should be mounted at a distance of 50 to 300 mm To ensure the safe operation the working temperature should be kept below 40ºC Electrical installation should be done only by a skilled electrical engineer and in accordance with all nationa...

Страница 7: ...Standard Simco 5x0 34 mm2 M12 Male Female cable 62 5m 45m 15m Type power supply 100 240 V AC Manager IQ Easy 100 240 V AC Extension IQ Easy Input Remote on off 10 30 V DC nominal Ri 10k Activation time 30 ms Output Output voltage emitters Max 9 kV positive and negative Current per emitter to earth Max 50 µA High voltage OK HV OK Supply voltage 1 V max 50 mA Environment Usage Industrial indoor usag...

Страница 8: ... IQ Easy Ex Speed 90 2790 mm In increments of 60 mm Dimensions exclusive Mounting brackets Tot length Eff length 250 mm with protective hose Tot length Eff length 180 mm without protective hose Width 30 mm Height 52 mm Weight 2 2 kg m Enclosure Aluminum PA6 PUR Universal Mounting brackets PA66 6 Image 4 1 1 Dimensions Performax IQ Easy Ex Speed ...

Страница 9: ... prevent any electrical shock when touched Connect the ground terminal on the anti static bar to a grounded part of the machine with a wire of a minimum size of 4mm2 Use the Performax IQ Easy Ex Speed always in combination with the Ex Status Module and IQ Easy Manager and or Extension IQ Easy The anti static bar is powered and controlled via the IQ Easy Platform See the list of spare parts and acc...

Страница 10: ...re the static electricity problem occurs Place with an optimal distance from the material that should be neutralized o 100 300 mm Performax IQ Easy Ex o 50 300 mm Performax IQ Easy Ex Speed With the emitters in the direction of the material to be neutralized Ensure that no material can come between the emitters and the material to be neutralized Attach the cable properly into the machine to preven...

Страница 11: ...B 5 4 Mounting brackets The anti static bars are provided with at least two mounting brackets with which the anti static bars can be attached in many different ways Image 5 4 1 Mounting brackets Performax IQ Easy Ex Speed dimensions and mounting options ...

Страница 12: ... the same direction Use suitable M5 fixing materials 3 Slide the brackets 4 on the anti static bar 5 Place the anti static bar with brackets on the mounting feet and push the brackets 4 in the opposite direction of the three triangles Lock the bracket 4 by tightening at least one of the two set screws 7 a screw is on both sides Position the ionization points above the material to be neutralized Se...

Страница 13: ...ypes are available 5 8 Connecting the Anti static bar Warning Observe the warnings at the beginning of this chapter The Ex Status Module must be mounted outside the Ex zone Use the Performax IQ Easy Ex Speed always in combination with an Ex Status Module Never connect the Performax IQ Easy Ex Speed directly to the power supply this is because the Ex Status Module contains the required fuse 0 5 AT ...

Страница 14: ...ide Push the protective hose into the fitting of the ionization bar until the yellow seal is no longer visible see image 5 8 2 5 Insert the grey clip into the fitting with the slot facing the outside so it can be removed with a screw driver if required see image 5 8 2 6 Push a yellow seal on the protective hose on the status module side When needed strip the cable according picture 5 8 2 7 mount p...

Страница 15: ...V1_4 77 GB Image 5 8 2 3 Length protective hose Image 5 8 2 4 Yellow seal on protective hose Image 5 8 2 5 Protective hose in fitting Image 5 8 2 6 Clip in fitting Image 5 8 2 7 Strip the cable Image 5 8 2 8 Mounting of fitting on Status Module ...

Страница 16: ...ing the outside 2 so it can be removed with a screw driver if required Then replace the cover and fasten with the screws Colour Connection Number Brown 24 V 1 White A 2 Blue 0 V 3 Black B 4 Yellow green or grey Earth 5 Image 5 8 2 10 Fixing a protective hose to the fitting 1 2 Connect the cable according to the table below Image 5 8 2 9 Connection wiring Performax Easy EX Speed with the Status Mod...

Страница 17: ...le to the desired length strip the cable according to figure 5 2 8 7 and mount proper ferrules to the end of the wires Turn the gland in the Status Module and run the cable through the gland Tighten the clamp ring of the bolt for good sealing and relief from straining Connect the cable according to the table below place the cover and screw tightly Image 5 8 2 11 Wiring connection Performax Easy EX...

Страница 18: ...onnected during operation of the IQ Manager Easy Hence it doesn t need to be switched off Image 5 8 3 2 Wiring connectors brown blue GND yellow green or grey brown black white white yellow green or grey black blue Ex Status Module cable side view Female connector M12 Manager Extension IQ Easy cable side view Male connector M12 2 white 1 brown 5 yellow green or grey 3 blue 4 black 2 white 3 blue 5 ...

Страница 19: ...param appears on the info screen from the bar on the Manager or when the bar is not reqognized the Manager must be updated with the latest software Download the latest software version via www simco ion co uk software and follow the Upgrade instructions as described in the Manager manual When the M12 connection cable connects the anti static bar and the IQ Easy platform communication will be estab...

Страница 20: ...the password and confirm with or return directly to the system settings page of the Manager if no password is required Click on and go to the device to check or change the parameters by clicking on behind the parameter or desired action By clicking you will return to the main screen 6 3 Calibrating the Performax IQ Easy Ex through the IQ Easy Platform The anti static bar should be calibrated when ...

Страница 21: ...ng on the application the static charge will be neutralized and a small residual charge will remain 2 Manual not currently available For test applications or very specific applications the ratio between positive and negative ions can be set manually This is done by entering a ratio number Usually an even number of positive and negative ions will be produced 0 fixed By entering a number other than ...

Страница 22: ...Click on Operation mode Select the desired operation mode Auto tune Manual CLFB is currently unavailable 6 4 1 Operation Mode Manual Once Manual mode is selected go to the following page symbol near the parameter Balance Click Balance offset and specify the desired positive or negative ionization with a number from 100 to 100 Confirm the selection by clicking The ionization is now continued with t...

Страница 23: ...m The anti static bar will then calculate using the average measurement values of the active enabled segments To disable a segment click Enabled segments Select the segments to be disabled Confirm selection with Go with the previous page symbol to the parameter Operation mode Select CLFB The sensor bar should now be connected to the Performax IQ Easy Ex bar The anti static bar will now use the ave...

Страница 24: ...Machine position Mounting distance Web width Web speed These are information parameters neither the bar or the Manager will use for calculations Select the information page with the parameters to be changed by n x parameter enter name of value confirm with 6 7 Switching the bar on off remotely through the remote on off input on the Manager or via fieldbus expert mode If desired the bar can be swit...

Страница 25: ...azardous areas Connect the field strength meter with the grounding keep a minimum distance of 30 cm from the anti static bar Measure the static charge of the material before and after it has passed the anti static bar The measured charge must have minimized after the material has passed the anti static bar 7 2 Checking functionalities via the LED s The color of the status LED s of the anti static ...

Страница 26: ...y or covered this value will drop Should the bar be set to standby this value will be 0 and the value between brackets will indicate the most recent value e g 0 98 Ionization current uA both the negative and the positive ionization current that the bar provides will be displayed here Balance offset 40 0 indicates the ratio of the ion output Depending on the selected Operation mode this value will ...

Страница 27: ...V NOT OK the bar is turned off or the HV doesn t function properly CLEAN BAR the efficiency has dropped below the clean bar warning level 7 3 4 Data log tab In the Data log tab all available measurement data of the bar is logged at fixed times If the parameter Datalogging is activated these values will also be saved in the log file of the Manager The interval between logging is determined by the s...

Страница 28: ...smount the anti static bar as described in chapter 5 Remove the anti static bar from the Ex zone Clean the anti static bar with a suitable cleaning material e g Isopropylalcohol By very heavy contamination Veconova 10 can also be used www eco nova nl Let the anti static bar dry completely before putting back into use Mount the anti static as described in chapter 5 9 Faults Warning Disconnect the p...

Страница 29: ...z Anti static bar over loaded Anti static bar contaminated Clean Anti static bar Anti static bar mounted too close to conductive machine parts Reposition the Anti static bar LED on anti static bar blinks red green 1Hz and Led on Ex Status Module blinks green 1Hz No poor ionization though High voltage on the emitters Anti static bar contaminated Clean Anti static bar Emitters are damaged Replace th...

Страница 30: ...epaired For ordering replacement parts see the list of replacement parts By problems or questions contact Simco Ion or the local representative Simco Ion provides advice on sending items for repairs as below Follow the procedure by visiting www simco ion co uk repair Ensure the anti static bar is properly packed and be sure to clearly state the reason for return For dismounting the anti static bar...

Страница 31: ...PerformaxIQEasyEx_UM_9752153510_NL_D_GB_FR_V1_4 93 GB Replacement parts ...

Страница 32: ...emale straight 5 pin 5m 7519020366 Device cable M12 female straight 5 pin 10m 12 7519020390 Device cable M12 female male straight 2 m 7519020391 Device cable M12 female male straight 5 m 7519020392 Device cable M12 female male straight 10 m 7519020386 Device cable M12 female male straight 5 m for cable carrier 7519020387 Device cable M12 female male straight 10 m for cable carrier 7519020383 Devic...

Страница 33: ...B T4 Gb Ex mb IIIB T135 C Db Notified Body EC type exam quality Baseefa 1180 Buxton UK EC Type Examination Certificate Baseefa17ATEX0012X Used Harmonized Standards The product is assessed and confirmed to comply to the Essential Health and Safety Requirements from the ATEX directive 2014 34 EU EN60079 0 2012 A11 2013 EN60079 18 2015 Other Standards and Specifications used Electromagnetic Compatibi...

Отзывы: