8
│
GB
SFR 3.7 B2
–
Fix the blue rod back in place with the
nozzle
. Ensure that the sealing rings are
correctly inserted.
–
Replace the dirt container
on the motor
unit
by pushing the front part into the
motor unit
and then pushing the rear part
downwards so that the dirt container
clicks firmly into place.
–
Push the vacuum attachment
onto the
motor unit
.
■
Wipe the charger
0
with a damp cloth. Ensure
that the charger
0
is completely dry before
reconnecting it to the mains.
Storage
■
Store the cleaned appliance in a clean, dust-free
and dry location.
Troubleshooting
Defect
Cause
Solution
The appliance is
not working.
The appliance is not charged.
Charge the appliance.
The appliance is defective.
Contact Customer Services.
Streaks keep
appearing during
cleaning.
The blade is dirty.
Clean the blade.
The blade is worn.
Remove the blade sideways from
the vacuum attachment
.
Moisten the blade at the round
end with water or detergent, turn
it over and push it back into the
vacuum attachment
.
Too much cleaning agent has been added.
Use less cleaning agent.
The spray bottle
does not work.
There is no water/cleaning agent in the
spray bottle.
Refill the spray bottle with water/
cleaning agent.
The spray bottle is defective.
Contact Customer Services.
The tip of the spray bottle is set to OFF.
Turn the tip to SPRAY or
STREAM.
If the malfunction cannot be corrected with the above suggestions, or if you have found
some other kind of malfunction, please contact our Customer Service.