Silver King SKFDI18 115V Скачать руководство пользователя страница 1

 

 

 
 
 
 

 

 

 

 

 

 

 

 

 
 
 
 
 

 
 
 
 
 
 
 
 

 

 

Specifications Subject to Change Without Notice. 

 

Marmon Foodservice Technologies 
355 Kehoe Blvd., Carol Stream, IL 60188 
Contact: (800) 328-3329  Silverking.com 
 

Technical Manual 

and 

Replacement Parts List 

Ice Cream Cabinets 

MODEL SKFDI18 115V 

MODEL SKFI18 115V 

FORM NO. 45322-SK   REV E  07/2022 

Содержание SKFDI18 115V

Страница 1: ... Notice Marmon Foodservice Technologies 355 Kehoe Blvd Carol Stream IL 60188 Contact 800 328 3329 Silverking com Technical Manual and Replacement Parts List Ice Cream Cabinets MODEL SKFDI18 115V MODEL SKFI18 115V FORM NO 45322 SK REV E 07 2022 ...

Страница 2: ...s with a dual hertz rating no adjustments are required for normal operation If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This refrigeration unit is not intended to be used at altitudes higher than 2000 meters Do not store explosive substances such as aerosol cans with a flammable propellant in this...

Страница 3: ...efrost refrigerator freezer Do not puncture refrigeration tubing Caution Risk of fire or explosion Flammable refrigerant used Consult repair manual owner s guide before attempting to service this product All safety precautions must be followed Caution Risk of fire or explosion To be repaired only by trained service personnel Use only Silver King approved replacement parts Flammable refrigerant use...

Страница 4: ...ample open flames an operating gas appliance or an operating electric heater Do not pierce or burn Be aware that refrigerants may not contain an odor WARNING Keep any required ventilation openings clear of obstruction Notice that servicing shall be performed only as recommended by manufacturer CAUTION Always be sure to keep area around the unit clean and free of clutter Failure to keep this area c...

Страница 5: ...ld be washed using a warm mild soapy water solution and a sponge or cloth LOCATION When locating your countertop drop in display merchandiser convenience and accessibility are important considerations but the following installation guidelines must be followed For SKFDI18 when installed in a countertop provisions need to be in place for the unit to receive proper ventilation for the compressor Do n...

Страница 6: ...5 ...

Страница 7: ...ally toxic or flammable atmospheres Ensure that the leak detection equipment being used is suitable for use with all applicable refrigerants i e non sparking adequately sealed or intrinsically safe Presence of Fire Extinguisher If any hot work is to be conducted on the refrigerating equipment or any associated parts appropriate fire extinguishing equipment shall be available to hand Have a dry che...

Страница 8: ...rking Discharge capacitors in a way that won t cause any spark using a Supco CapDis tool That no live electrical components and wiring are exposed while charging recovering or purging the system that there is continuity of earth bonding Repairs to Sealed Components During repairs to sealed components all electrical supplies shall be disconnected from equipment being worked upon prior to any remova...

Страница 9: ...l be removed extinguished If a leakage of refrigerant is found which requires brazing all of the refrigerant shall be recovered from the system or isolated by means of shut off valves in a part of the system remote from the leak Removal and Evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However for flammable refr...

Страница 10: ...ept in an appropriate position according to the instructions WARNING Ensure that the REFRIGERATING SYSTEM is earthed prior to charging the system with refrigerant WARNING Label the system when charging is complete if not already WARNING Extreme care shall be taken not to overfill the REFRIGERATING SYSTEM Prior to recharging the system it shall be pressure tested with the appropriate purging gas Th...

Страница 11: ...d from the electrical receptacle and remove or open the Lid Assembly After the frost has melted or come loose from the walls wipe out the cabinet interior Do not attempt to scrape or chisel off the frost as you could do irreparable damage to the unit MAINTENANCE Preventative maintenance is minimal although these few steps are very important to continued trouble free operation and maximizing the li...

Страница 12: ...11 ...

Страница 13: ...577 9 TEMPERATURE CONTROL 115V 39592 10 POWER CORD 115V 32199 SK 11 DRIER 22677 SK 12 COVER ASSEMBLY 39542 13 BRACKET HINGE COVER RH 37413 14 BRACKET HINGE COVER LH 37414 15 KNOB COVER 99474 16 HINGE COVER 25226 SK 17 GUARD FRONT LEFT 39525 18 GUARD REAR RIGHT 39526 19 TEMPERATURE PROBE NOT SHOWN 38822 20 CAPILLARY TUBE NOT SHOWN 99771 21 SERVICE PANEL FRONT REAR SKFI18 ONLY 41661 22 LEG KIT 6 SKF...

Страница 14: ...13 ...

Страница 15: ... s reading to Table 1 Analyze Results If the resistance and temperature are similar then the thermistor is working properly and does not need to be replaced If the resistance and temperature are not similar or the resistance s value is not on Table 1 then the thermistor is not working properly and needs to be replaced If the resistance reads over limit then the thermistor is not working properly a...

Страница 16: ...to food loss Unit is compromised by adding excess weight or adhering nonapproved components to the frame Combining the equipment with hardware fixtures accessories or other equipment not provided by Silver King Misuse of the Equipment or use of the Equipment not in accordance with the Technical Manual Warranty excludes consumables or replacement components such as shelving trays gaskets etc Warran...

Страница 17: ...w to be inefficient or inoperative due to defects in material or factory workmanship It is the original purchaser s responsibility to return the serial plate of the defective compressor or at Silver King s option the complete compressor to the factory Failure to do so will void this limited compressor warranty This limited compressor warranty shall be limited to parts only after the WARRANTY perio...

Страница 18: ...iled within 30 days from date of service PRODUCT ORDERING INFORMATION Call us toll free at 1 800 328 3329 or 1 763 923 2441 Fax us at 1 763 553 1209 Visit www silverking com for stocking distributor equipment specs and current price list for your area SERVICE PARTS ORDERING INFORMATION Call us toll free at 1 800 328 3329 Select prompt 1 for Equipment Service and Tech Support or prompt 2 for Parts ...

Страница 19: ...VER KING SHALL HAVE NO OBLIGATION OR LIABILITY FOR CONSEQUENTIAL OR SPECIAL DAMAGES INCLUDING BUT NOT LIMITED TO INDIRECT PUNITIVE DAMAGES LOSS OF USE LOSS OF PRODUCT DOWNTIME OR LOST PROFITS ARISING OUT OR RELATED TO OR CONNECTED IN ANY WAY WITH THE PRODUCT OR ITS USE Silver King prices subject to change without notice Note Additional Terms and Conditions of sale may apply Notice Specifications s...