background image

 

 
 

The standard counter-top display merchandiser is equipped with an eight (8) foot power cord that requires a 115 Volt, 

60 Cycle, 1 phase properly grounded electrical receptacle.  The power cord comes with a 3 prong plug for grounding 

purposes.  Any attempt to cut off the grounding spike or to connect to an ungrounded adapter plug will void the 

warranty, terminate the manufacturers responsibility and could result in serious injury. 

 

The electrical circuit must be protected with a 15 or 20 ampere fuse or breaker.  The unit must be isolated on a circuit 

and not plugged into an extension cord. 

 

OPERATION 

Initial Start Up 

After satisfying the installation requirements, the counter-top display merchandiser is ready to start.  The unit will start 

when the power cord is connected to the required power source.  If the compressor does not start when the unit is 

initially plugged in, check to make sure that the Temperature Control is not in the ‘off’ position.  Allow the unit to run for 

two hours before loading it with product.  When loading the unit with product do not load above the ‘product load line’ 

indicated on the liner. 

 

Temperature Control 

The Temperature Control is located on the back of the unit in the lower right hand corner.  Turn the Temperature 

Control stem clockwise to obtain colder cabinet temperatures and vice versa.  Allow the unit a minimum of two hours to 

respond to a control setting adjustment. 

 

Defrost 

The Silver King counter-top display merchandiser is a manual defrost unit.  The unit should be defrosted whenever the 

walls accumulate a frost layer that is 1/4 inch thick. To defrost the unit, either turn the Temperature Control stem to the 

‘off’ position (fully counterclockwise) or disconnect the Power Cord from the electrical receptacle, and remove the Lid 

Assembly.  On top of the center divider on the model SKCTM, there is a Defrost Plate (see parts list), pull up on the 

Defrost Plate to remove it from the cabinet and break up the frost buildup on the center divider.  The center divider 

itself is not removable and no attempt to do so should be made.  After the frost has melted or come loose from the 

walls, wipe out the cabinet interior.  Do not attempt to scrape or chisel off the frost as you could do irreparable damage 

to the unit. 

 

MAINTENANCE 

Preventative maintenance is minimal although these few steps are very important to continued trouble free operation 

and maximizing the life of your appliance. 

 

Cabinet Surfaces 

The cabinet interior and exterior surfaces should be cleaned periodically with a solution of warm water and mild soap 

and wiped dry with a soft cloth.  Should a surface become discolored, do not attempt to clean with an abrasive 

cleanser or scouring pad.  Use a soft cleanser and rub with the grain of the metal to avoid scratching the surface.   

 

Condenser 

Periodically, accumulated dust must be removed from the condenser.  First, disconnect the unit from the power supply.  

To clear the dust, blow air though the condenser fins or remove the back panel and brush the dust from the backside 

of the condenser. 

MODEL 

SERIAL NO. 

DATE INSTALLED 

Содержание SKCTM

Страница 1: ...s Subject to Change Without Notice A Division of Stevens Lee Company 1600 Xenium Lane North Minneapolis MN 55441 3787 Phone 763 553 1881 Technical Manual and ReplacementPartsList CounterTop Merchandis...

Страница 2: ...tion and a sponge or cloth Lid For shipping purposes the Lid Assembly has been taped to the cabinet Remove all the tape from the Lid Assembly and install the Lid Assembly on the cabinet by holding in...

Страница 3: ...unter top display merchandiser is a manual defrost unit The unit should be defrosted whenever the walls accumulate a frost layer that is 1 4 inch thick To defrost the unit either turn the Temperature...

Страница 4: ...la Tapa ha sido pegada con una cinta al gabinete Retire la cinta de la tapa e inst lela en el gabinete sujetanto los pasadores de bisagra en la parte trasera de la Tapa e insert ndolos en los orifici...

Страница 5: ...nto El expendedor de mercader as para mostrador Silver King es una unidad de descongelamiento manual La unidad debe ser descongelada cada vez que las paredes acumulen una capa de escarcha de un grosor...

Страница 6: ...e et une ponge ou un chiffon Couvercle Dans un but d exp dition l ensemble de couvercle a t attach avec du scotch l armoire Retirez tout le ruban de l ensemble de couvercle et installez ce dernier sur...

Страница 7: ...unit d givrage manuel L unit doit tre d givr e chaque fois qu une couche de givre ayant une paisseur de 1 4 pouce s est accumul e sur les parois Pour d givrer l unit tournez la tige de r glage de temp...

Страница 8: ...n der Hinterseite des Deckelaufbaus gedr ckt halten und in die Schanierbefestigungen unterhalb dem beleuchteten Schild einlegen Licht Der Lichtschalter befindet sich hinten am Geh use in der oberen li...

Страница 9: ...ie neue Einstellung des Temperaturreglers zu reagieren Abtauen Die counter top display merchandiser muss manuell abgetaut werden Das Ger t sollte abgetaut werden sobald die Eisschicht an den W nden 0...

Страница 10: ...9...

Страница 11: ...10 REPLACEMENT PARTS LIST MODEL SKCTM...

Страница 12: ...11 FORM NO 26227 REV D...

Отзывы: