4-3-2 D
ESCRIPTION
OF
SMS R
ECEIVED
BY
THE
USER
SMS
Examples
Description
Config OK
Admin : +33xxxxxxxxx
Warning, no probe
Config OK
Admin : +33612345678
Warning, no probe
The administrator receives this message after the configuration of device.
If no probe is detected on the input sensor, you receive this alert: “
Warning, no probe.
”
ERR Config
ERR Config
The administrator receives this message when the product configuration was not well performed
New Admin :
+33xxxxxxxxx
New Admin : +33612345678
When the administrator changes is received by the old
and
the new administrator, with+
33xxxxxxxxx
as the
phone number
of the new administrator
Adding the user :
+33xxxxxxxxx
Adding the user : +33612345679
The administrator receives this message after adding a new user. The new user also receives this message.
Error : not add a third
user
Error : not add a third user
The administrator receives this message if he tried to add a third user
Invalid Phone Number
Invalid Phone Number
The administrator receives this message if the entered phone number does not begin with +33 or/and if the
next 9 characters are not numbers.
Deleting the user :
+33xxxxxxxxx
Deleting the user : +33612345679
The administrator receives this message after deleting a new user.
User 1 : +33xxxxxxxxx
User 2 : +33xxxxxxxxx
User 1 : +33633863675
User 2 : +33633863675
The administrator receives this message as answer to the “
USERS?
”
command.
Language ENGLISH
Language ENGLISH
Confirmation of the language selection
Setpoint : XX
Setpoint : 16
The administrator receives this message after setting up the temperature setpoint.
Invalid setpoint
Invalid setpoint
The administrator receives this message if the temperature setpoint if lower than 6 or greater than 20
Output 2 ON
Output 2 ON
Confirmation of the switch-on device connected to the output 2
Output 2 OFF
Output 2 OFF
Confirmation of the switch-off device connected to the output 2
Output 2 in mode
heating zone
Output 2 in mode
heating zone
Confirmation of the passage in
heating zone
mode of the output 2
Heating : XXXX
Setpoint : XX
Temperature : XX
Output 2 : XXXX
Alarm1 XX
Alarm2 XX
Batteries XX
Heating : ECO
Setpoint : 16
Temperature : 19
Output 2 : Electrical device ON
ALARM 1 DETECTED
No alarm 2
Batteries OK
Indication of the current mode (
PRESENT or ECO
), the value of the temperature setpoint (°C), the value of
the current temperature (if no sensor is connected you will have the message: «
Warning, no probe
»), the
current setting of the output 2 (
Heating zone, Electrical device ON or Electrical device OFF)
.
You will also have the state of the 2 alarms inputs
(ALARM 1 DETECTED or No alarm 1, ALARM 2
DETECTED or No alarm 2)
and then the current batteries
(Low batteries or Batteries OK)
.
This message is send as 2 SMS
Heating : PRESENT
Heating : PRESENT
Confirmation of the passage in
PRESENT
mode
Heating : ECO
Heating : ECO
Confirmation of the passage in
ECO
mode
Invalid command or
unauthorized control
Invalid command or unauthorized
control
This message is received when a wrong command (or an unauthorized order) has been sent
16