28
Recurring Syntax Elements
Table 4 Recurring Syntax Elements
Recurring Syntax
Syntax Value
raid-level
(0 | 1 | 3 | 5 | 6)
repository-raid-level
(1 | 3 | 5 | 6)
capacity-spec
integer-literal
[KB | MB | GB | TB |
Bytes]
segment-size-spec
integer-literal
boolean
(TRUE | FALSE)
user-label
string-literal
Valid characters are alphanumeric, the dash, and the
underscore.
user-label-list
user-label
{
user-label
}
create-raid-vol-attr-
value-list
create-raid-volume-attribute-value-pair
{
create-raid-volume-attribute-value-pair
}
create-raid-volume-
attribute-value-pair
capacity=
capacity-spec
| owner=(a | b) |
cacheReadPrefetch=(TRUE | FALSE) |
segmentSize=
integer-literal
|
usageHint=
usage-hint-spec
noncontroller-trayID
(0-99)
slotID
(1-32)
portID
(0-127)
drive-spec
trayID,slotID
or
trayID,drawerID,slotID
A drive is defined as two or three interger literal values
separated by a comma. Low-density trays require two values.
High-density trays, those trays that have drawers, require
three values.
drive-spec-list
drive-spec
drive-spec
trayID-list
trayID
{
trayID
}
esm-spec-list
esm-spec
{
esm-spec
}
esm-spec
trayID,
(left | right)
hex-literal
0xhexadecimal-literal
volumeGroup-number
integer-literal
filename
string-literal
error-action
(stop | continue)
drive-channel-identifier
(four drive ports per tray)
(1 | 2 | 3 | 4)
Содержание InfiniteStorage 4000 Series
Страница 34: ...22 ExitStatus ...
Страница 48: ...36 Adding Comments to a Script File ...
Страница 110: ...98 Starting Stopping and Resuming a Snapshot Legacy Rollback ...
Страница 168: ...156 Interaction with Other Premium Features ...
Страница 182: ...170 Interaction with Other Premium Features ...
Страница 192: ...180 SSD Cache Management Tasks ...
Страница 216: ...204 RecoveryOperations ...
Страница 218: ...206 Show Storage Array ...
Страница 219: ...Appendix A Examples of Information Returned by the Show Commands 207 ...
Страница 220: ...208 Show Storage Array ...
Страница 221: ...Appendix A Examples of Information Returned by the Show Commands 209 ...
Страница 222: ...210 Show Storage Array ...
Страница 223: ...Appendix A Examples of Information Returned by the Show Commands 211 ...
Страница 224: ...212 Show Storage Array ...
Страница 225: ...Appendix A Examples of Information Returned by the Show Commands 213 ...
Страница 226: ...214 Show Storage Array ...
Страница 227: ...Appendix A Examples of Information Returned by the Show Commands 215 ...
Страница 228: ...216 Show Storage Array ...
Страница 229: ...Appendix A Examples of Information Returned by the Show Commands 217 ...
Страница 230: ...218 Show Storage Array ...
Страница 231: ...Appendix A Examples of Information Returned by the Show Commands 219 ...
Страница 233: ...Appendix A Examples of Information Returned by the Show Commands 221 ...
Страница 234: ...222 Show Controller NVSRAM ...
Страница 252: ...240 ShowDrive Show Drive The show drive command returns information about the drives in a storage array ...
Страница 253: ...Appendix A Examples of Information Returned by the Show Commands 241 ...
Страница 254: ...242 ShowDrive ...
Страница 255: ...Appendix A Examples of Information Returned by the Show Commands 243 ...
Страница 256: ...244 ShowDrive ...
Страница 257: ...Appendix A Examples of Information Returned by the Show Commands 245 ...
Страница 258: ...246 ShowDrive ...
Страница 268: ...256 ConfigurationUtility ...
Страница 275: ......
Страница 276: ...Copyright 2012 NetApp Inc All rights reserved ...