Chapter 11: Maintaining a Storage Array
181
11
Maintaining a Storage Array
Maintenance covers a broad spectrum of activity with the goal of keeping a storage
array operational and available to all hosts. This chapter provides descriptions of
commands you can use to perform storage array maintenance. The commands are
organized into four sections:
Routine maintenance
Performance tuning
Troubleshooting and diagnostics
Recovery operations
The organization is not a rigid approach, and you can use the commands as
appropriate for your storage array. The commands listed in this chapter do not cover
the entire array of commands you can use for maintenance. Other commands,
particularly the
set
commands, can provide diagnostic or maintenance capabilities.
Routine
Maintenance
Routine maintenance involves those tasks that you might perform periodically to
make sure that the storage array is running as well as possible or to detect conditions
before they become problems.
Running a Media
Scan
Media scan provides a way of detecting drive media errors before they are found
during a normal read from or write to the drives. Any media scan errors that are
detected are reported to the Event Log. The Event Log provides an early indication of
an impending drive failure and reduces the possibility of encountering a media error
during host operations. A media scan is performed as a background operation and
scans all data and redundancy information in defined user volumes.
A media scan runs on all of the volumes in the storage array that have these
conditions:
Has Optimal status
Has no modification operations in progress
Has media scan enabled
Errors that are detected during a scan of a user volume are reported to the Major
Event Log (MEL) and handled as follows:
Unrecovered media error
– The drive could not read the requested data on its
first try or on any subsequent retries. The result of this action is that for volumes
with redundancy protection, the data is reconstructed, rewritten to the drive, and
verified, and the error is reported to the Event Log. For volumes without
redundancy protection, the error is not corrected, but it is reported to the Event
Log.
Содержание InfiniteStorage 4000 Series
Страница 34: ...22 ExitStatus ...
Страница 48: ...36 Adding Comments to a Script File ...
Страница 110: ...98 Starting Stopping and Resuming a Snapshot Legacy Rollback ...
Страница 168: ...156 Interaction with Other Premium Features ...
Страница 182: ...170 Interaction with Other Premium Features ...
Страница 192: ...180 SSD Cache Management Tasks ...
Страница 216: ...204 RecoveryOperations ...
Страница 218: ...206 Show Storage Array ...
Страница 219: ...Appendix A Examples of Information Returned by the Show Commands 207 ...
Страница 220: ...208 Show Storage Array ...
Страница 221: ...Appendix A Examples of Information Returned by the Show Commands 209 ...
Страница 222: ...210 Show Storage Array ...
Страница 223: ...Appendix A Examples of Information Returned by the Show Commands 211 ...
Страница 224: ...212 Show Storage Array ...
Страница 225: ...Appendix A Examples of Information Returned by the Show Commands 213 ...
Страница 226: ...214 Show Storage Array ...
Страница 227: ...Appendix A Examples of Information Returned by the Show Commands 215 ...
Страница 228: ...216 Show Storage Array ...
Страница 229: ...Appendix A Examples of Information Returned by the Show Commands 217 ...
Страница 230: ...218 Show Storage Array ...
Страница 231: ...Appendix A Examples of Information Returned by the Show Commands 219 ...
Страница 233: ...Appendix A Examples of Information Returned by the Show Commands 221 ...
Страница 234: ...222 Show Controller NVSRAM ...
Страница 252: ...240 ShowDrive Show Drive The show drive command returns information about the drives in a storage array ...
Страница 253: ...Appendix A Examples of Information Returned by the Show Commands 241 ...
Страница 254: ...242 ShowDrive ...
Страница 255: ...Appendix A Examples of Information Returned by the Show Commands 243 ...
Страница 256: ...244 ShowDrive ...
Страница 257: ...Appendix A Examples of Information Returned by the Show Commands 245 ...
Страница 258: ...246 ShowDrive ...
Страница 268: ...256 ConfigurationUtility ...
Страница 275: ......
Страница 276: ...Copyright 2012 NetApp Inc All rights reserved ...