Transmitter Features: 

DB41-MC transmitters are battery operated. DB41-MC is coded at the manufacturer with a unique address ID. DB41-MC is designed 
to alert when a DC voltage is applied. Transmitter has a test button for programming and follow on operational testing. When 
activated the RED LED will illuminate and the DB41-MC will transmit a doorbell alert to the Silent Call Medallion series receiver. 
Low Battery YELLOW LED will flash every 10 seconds when batteries are in need of replacement. 
 

Transmitter Mounting And Location:

  

 

The DB41-MC Medallion Series Transmitter is designed for indoor use only. The transmitter case has provisions for mounting to a 
nail or screw on the wall. Velcro strip is also provided for mounting on desktop or wall. Avoid mounting transmitter near large metal 
objects, other transmitting devices in close proximity or high current appliances that will degrade the transmitter / receiver operation. 
Test transmitter mounting location before mounting to ensure proper system operation. Adjust antenna for best results. Transmission 
range with a Silent Call Medallion Series receiver is approximately 500 feet. 
 

Installation: 

1.

 

DB41-MC requires DC voltage (12vdc~24vdc) to activate. DB41-MC wire connections are NOT polarity sensitive. 

2.

 

Review doorbell/Intercom system instructions to determine connections needed.  

3.

 

Attach the two wires from the DB41-MC to the connections identified in Step 2.   

4.

 

Mount the DB41-MC transmitter. 

5.

 

Pair DB41-MC to intended Medallion Receiver. Follow Programming procedure in Receiver installation manual. 

 

Operation: 

1.

 

Activate Doorbell/Intercom system.  

2.

 

The Red LED on the face of the transmitter will light up when system activated.  The transmitter then sends a RF signal to a 
preprogrammed Medallion Series Receiver activating the Doorbell alert.

 

 

Replacement Batteries: 

Use two AA 1.5V Alkaline Batteries. AA Batteries may be purchased from local retail stores. Transmitter is shipped with 2 AA 
Alkaline Batteries.  Batteries may also be purchased Online at 

www.silentcall.com

.   

 

Regulatory Information Notice

This device complies with Industry Canada license-exempt RSS standard(s). 
Operation is subject to the following two conditions: (1) This device may not cause harmful 
interference, and (2) this device must accept any interference received, including interference that may cause undesired 
operation of the device. This equipment has been tested and found to comply with the limits 
for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generates, uses 
and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause 
harmful interference to radio communications. However, there is no guarantee that interference 
will not occur in a particular installation. If this equipment does cause harmful interference 
to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to 
try to correct the interference by one or more of the following measures: 

• Reorient or relocate the receiving antenna. 
• Increase the separation between the equipment and the receiver 
• Connect the equipment into an outlet on a circuit different from that 
  to which the receiver is connected. 
• Consult the dealer or an experienced radio/television technician for help  
 

Unauthorized changes or modifications could void the user’s authority to operate the equipment. 

 

 
 
 
 
 