Quick start guide UM3A-2212-EU-PSU
Smoke / Carbon Monoxide Monitor with inline PSU
CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENT-ALERT.CO.UK CLOFIELD LTD. UK
TEL 01246 260045
MOVE KEY
DOWN
TO SWITCH
ON
Any questions? Call us on 01246 450789
1
2 3 4 5
B
5
4
3
2
1
ON /OFF
O
N
1
2
3
1.
A
4
A
4
5
4
5
SW3935
I/P:
AC 100
-240V
O/P: DC 9V 1.3A
Power supply
Connect the power supply to
a 13 Amp fused spur.
WARNING
This product should only be installed by
a suitably qualified person.
Clofield take no responsibility for damage
caused by incorrect fitting.
WARNING! Your device and its accessories are not toys. They may contain small parts. Keep them out of the reach of small children.
Test button
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
UM3A-2212-EU-PSU
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENT-ALERT.CO.UK CLOFIELD LTD. UK
TEL 01246 260045
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 =
Audio
Monitor
ing
6 = Zone Multipl
ier (7
-12)
7 = Short
Audio
Delay
8 = Medium
Audi
o Delay
7 & 8 = Long
Audio
Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10
Mins
9 & 10 = PIR Dela
y 15 mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY
DOWN
TO SWITCH
ON
Alkaline
NOTE: if this is done in
reverse order a low battery
signal will be sent out and
the test/send button will
shine orange instead of
green for up to 9 hours.
Power the unit.
WARNING. DO NOT APPLY MAINS VOLTAGE TO THE UNIT AS THIS WILL CAUSE IRREVOCABLE DAMAGE,
CAUSE INJURY AND CREATE A FIRE HAZARD
.
Volt-free relay / short circuit activation
The UM3A-2212-EU-PSU should ideally be connected to interconnected smoke
alarms via a normally open volt-free relay using terminals 1 & 3 as shown.
Low voltage activation
Link the Monitor via terminals 1 & 2 (middle and bottom terminals). Link the
LOW VOLTAGE Interlink Terminal within the device to terminal 2 (middle
terminal) on the monitor and the Neutral terminal within the alarm to Terminal 1
(bottom terminal) on the Monitor.
Activate the alarm system, this will cause the monitor to transmit a radio signal
and the green light on the front of the unit will go out momentarily.
Test the unit in position then fasten to the wall with the screw kit provided.
2. Interconnect smoke / heat / Carbon Monoxide connection
Switch the mains off,
remove the battery and
reset the unit using the
procedure in step 1.
●
●
●
This monitor will send a
fire signal by default.
It can be configured to transmit a
Carbon Monoxide signal (see reverse).
Connect a PP3 battery to the
unit then power the unit by
switching the mains on.
The test button will light
green, this is normal.
PLEASE NOTE
.
THIS PRODUCT
DOES NOT
COMPLY WITH BS5839-1 2002. HOWEVER, THE FIRE SAFE INTERFACE PANEL, ALSO
AVAILABLE FROM CLOFIELD LTD (PART NUMBER FSTX-2225-EU) DOES
.
1
3
1
2