PUSH

Status light

Test button

Configuration 

switch Cover

PP3 battery 

contacts

Screw cap

Screw cap

CCD4A-2220-EU 

CARE CALL 

MINI MAGNETIC
DOOR MONITOR

USE ALKALINE PP3 
9 V BATTERY ONLY

Batch 06/01/14 

www.silentalert.ie 

Silent Alert International, IRL 

Tel: +353 (0)1 247 9007

  Keys 1-4 System 

Channel

  Key 5=10 Sec Delay
  Key 6=20 Sec Delay

Keys 5+6=30 Sec Delay

  Key 7 Leave ON  

Key 8 Not Used

USE WITH MAGNET SUPPLIED

PP3 Battery

PUSH

PUSH

The light will then flash green 

several times to show the 

battery voltage. 

9 flashes = 9Volts in the battery. 

When a battery is first fitted the 

indicator light will flash red then 

green a few times.  

1.

Install a 9 volt PP3 alkaline or lithium battery 

making sure to observe the correct polarity.

PUSH

If the light flashes red at this 

point the battery is flat  

and will need to be replaced. 

To repeat the battery check remove the battery, press the test 

button then re-insert the battery to start the sequence again.

TD4A

 MONITOR

USE ALKALINE PP3 
9 V BATTERY ONLY

Batch 06/01/14 

www.silentalert.ie 

Silent Alert International, IRL 

Tel: +353 (0)1 247 9007

  Keys 1-4 System 

Channel

  Key 5=10 Sec Delay
  Key 6=20 Sec Delay

Keys 5+6=30 Sec Delay

  Key 7 Leave ON  

Key 8 Not Used

USE WITH MAGNET SUPPLIED

PUSH

1 2 3 4 5 6 7 8

Configuration switches shown 

with cover removed.

Input 

terminals

Standard operation

TM

S

i

lent

Alert

It is possible for the monitor to light up different keys on the Pager or SignWave. 

1 2 3 4 5 6 7 8

Move the relevant key 

to the right .

Press the test button 

and check the correct 

event is received by the 

Pager or SignWave

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

For more information on configuring the Mini Monitor please refer to the dedicated quick guide supplied 
with each unit. Alternatively, you can download the information from out website at www.silentalert.ie. 

This quick start guide explains the process of connecting Silent Alert equipment to certain Telecare communicators for 
DDA compliance. 
Whilst a wireless smoke alarm unit will alert the call centre, a deaf or hard of hearing person may miss the alarm and be 
unaware of the danger. By using a Silent Alert DDA kit, the user will be alerted immediately and can respond or react 
as necessary. This ensures deaf and hard of hearing people can be made aware of integrated Telecare smoke alarms 
whilst reducing false alarm call outs. 
The user will also be able to expand on the benefits of the Telecare system by having access to doorbell, telephone, baby 
alarm and door entry systems whilst still having the security of a remotely monitored smoke alarm and emergency pendant.

1 2 3 4 5 6 7 8

Move control keys 

5, 6 & 7 to the right. 

2.

3.

The monitor will now trigger 

when the telecare unit activates 

its external output. 

A fire signal will be sent to the 

Pager or SignWave when the 

Telecare relay activates.

4.

A

B

5

4

3

2

1

ON /OFF

O

N

Enabling deaf or hard of 
hearing people to respond to 
Telecare smoke alarms.

TM

S

i

lent

Alert

Compatible

TM

S

i

lent

Safe

F

i

r

Alert

e

TM

S

i

lent

Alert

Quick start guide DDA kit

Mini Monitor for use with Telecare Communicators

Any questions? Call us on

+353 (0)1 247 9007

This information is not intended to replace the manufacturers user instructions. The assistance of the Telecare 
providers technicians will be required to enable correct output.  

Connecting to Tynetec Reach+