![Siko MSA501 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/siko/msa501/msa501_user-manual_1270545032.webp)
Communication via
CAN bus (CANopen)
MSA501
Date: 12.10.2018
Art. No. 88734
Mod. status 330/18
Page 32 of 51
5.6.2.12
1011h: Restore Parameter
Object 1011h restores the factory settings of the device depending on the selection. The
string “load” must be sent as data content and the device reset thereafter. If the restored
parameters are intended to be permanently available, they must be stored via object
Subindex
00h
Description
indicates the largest supported sub-index
Access
ro
PDO-Mapping
no
Data type
UNSIGNED 8
Default
4h
EEPROM
no
Subindex
01h
Description
Reset all parameters to factory settings
Access
rw
PDO-Mapping
no
Data type
UNSIGNED 32
Default
1h
EEPROM
no
Data content
Write:
Byte 0
Byte 1
Byte 2
Byte 3
6Ch ("l")
6Fh ("o")
61h ("a")
64h ("d")
Read:
Bit 31 … 1 0, reserviert
Bit 0
1: Device permits loading of default parameters.
Subindex
02h
Description
Set only communication parameters to factory settings (1000h-1FFFh, CiA
DS-301)
Access
rw
PDO-Mapping
no
Data type
UNSIGNED 32
Default
1h
EEPROM
no
Data content
Write:
Byte 0
Byte 1
Byte 2
Byte 3
6Ch ("l")
6Fh ("o")
61h ("a")
64h ("d")
Read:
Bit 31 … 1 0, reserviert
Bit 0
1: Device permits loading of default parameters.