![Siko IKM360M Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/siko/ikm360m/ikm360m_user-manual_1270641055.webp)
Communication via CAN bus (CANopen and CANopen Safety)
IKM360M
Date: 21.01.2021
Art. No. 90444
Mod. status 222/20
Page 55 of 58
5.8.2.33
6211h: Safety inverted Slope long16 (Safety inverted longitudinal slope value)
The Safety inverted Slope long16 (Safety inverted longitudinal slope value) can be read byte
by byte via object 6211h.
Sub-index
00h
Description
indicates the largest supported sub-index
Access
const
PDO mapping
no
Data type
UNSIGNED 8
Default
2h
EEPROM
no
Sub-index
01h
Description
Safety inverted slope long16 1
st
Byte
Access
ro
PDO mapping
no
Data type
INTEGER 8
Default
0h
EEPROM
no
Sub-index
02h
Description
Safety inverted slope long16 2
nd
Byte
Access
ro
PDO mapping
no
Data type
INTEGER 8
Default
0h
EEPROM
no