IO-Link
AP10S
Date: 12.05.2020
Art. No. 90304
Mod. status 110/20
Page 42 of 44
5.4
DeviceAccessLocks
Index
(hex)
Name
Access Supported Access Locks
Comment
12 (0Ch)
DeviceAccessLocks rw
Data Storage
IO-Link Spec.
Local Parameterization
IO-Link Spec.
Table 28: DeviceAccessLocks
5.5
EventCodes
Value
Name
Type
Comment
6145(1801h)
Speed error
Error
Travel speed exceeded
6146(1802h)
Battery empty
Error
Battery undervoltage (dead)
20496 (5010h) Component malfunction Error
Various sensor errors
20498 (5012h) Battery low
Warning Charging state " critical"
25376 (6320h) Parameter error
Error
IO-Link Spec.
Table 29: EventCodes
5.6
ErrorCodes
Value
1
st
byte
Value
2
nd
byte
Name
Comment
80
xx
Error Code
IO-Link Spec.
V1.1.2 Annex D
81
xx
Vendor specific error code
00
Device application error, no details
11
Index not available
12
Subindex not available
20
Service temporarily not available
21
Service temporarily not available, local control
22
Service temporarily not available, device control
23
Write access denied
30
Parameter value out of range
31
Parameter value above limit
32
Parameter value below limit
33
Parameter length overrun
34
Parameter length underrun
35
Function not available
36
Function temporarily not available
40
Invalid parameter set
41
Inconsistent parameter set